Electrical Sequence

Refer the wiring diagram as needed.

The "Power" light on the board glows whenever
there is power to the machine (and the master
switch is ON).

If the machine is switched off at the master switch,
but is otherwise ready to go, switching the master
switch to ON does the following:

••

The bin empty and power lights on the circuit
board glow.

••

There is a 15 second delay

••

If there is enough water in the reservoir, the
circuit board will allow the machine to start up.

Start up consists of:

••

The compressor contactor coil receives power
from the circuit board.

••

The contactor is energized, connecting power to
the compressor, and the compressor starts.

••

The auger motor receives power from the circuit
board and starts.

••

As ice goes past the ice level sensors, the bin
empty light will stay on and  the machine will
continue to run, unless the ice stays between
the sensors for more than 15 seconds (bin full).
At that point, the bin empty light goes out, and
the machine shuts down.

Other reasons for shut down:

••

Low water level (as sensed by the thermistor in
the reservoir).

••

Excessive auger motor amp draw, measured by
the circuit board.

••

If the auger motor amp draw becomes
excessive twice in an hour, the auger motor is
shut down and the circuit board must be
manually reset. If this condition occurs it means
that the drive train is in need of cleaning.
maintenance or repair.

Shut Down consists of:

••

The compressor contactor opens

••

The compressor stops

••

The auger motor is run by the circuit board for 2
more minutes, clearing out ice in the
evaporator, and then

••

The auger motor no longer receives power from
the circuit board, and the auger motor stops.

After a 6 minute delay, If the ice level sensor is
clear (bin empty) for more than 15 seconds, the
machine will start up again.

Another purpose of the circuit board is to turn the
machine off if there is not enough water in the
machine.

••

When the water level  in the reservoir falls
below the tip of the water level sensor, the
machine will "shut down"

••

After a 6 minute delay, if the water refills the
reservoir, the machine will start up again.

Separate from the circuit board:

••

If the high pressure control (cut out switch)
opens,  the compressor will stop immediately
(through the contactor ). It must be manually
reset.

••

The master switch is the manual control for the
complete machine, but it is not a service
disconnect.

Ice Vending

••

When a user places a container in front of the
Touch Free ice sensor and below the ice
delivery chute, the circuit board connects power
to the bin drive motor and ice is dispensed for
as long as the container is present.  If the user
does not remove the container, ice will be
dispensed for 60 seconds and then stop.

••

When a user places a container in front of the
Touch Free water sensor, and below the water
spout, the circuit board connects power to the
water solenoid valve and water is dispensed. If
the user does not remove the container water
will be dispensed for 90 seconds and then stop.

Splash panel cleaning:

A switch, located to the left of the spout, may be
pushed to disable the Touch-Free sensor for
splash panel cleaning. It automatically resets after
2 minutes, or, if pushed within the 2 minutes,
resets the circuit board to enable the Touch Free
sensors.

TDE470

February 1995

Page 14

Содержание TDE470

Страница 1: ...age 2 To The Installer Page 3 For The Electrician Page 4 For The Plumber Page 5 Optional Kits Page 6 Wall Mount Kit KWB1 Page 7 Final Check List Initial Start Up Page 8 User Operation Page 9 Component...

Страница 2: ...voids the warranty Scotsman Ice Systems are designed and manufactured with the highest regard for safety and performance They meet or exceed the standards of UL NSF and CUL Scotsman assumes no liabili...

Страница 3: ...the water and have to be treated A water filter is always a good idea but does require regular maintenance to change the cartridge In some water conditions water treatment may be required Generally t...

Страница 4: ...censed electrician may be required in some situations Remove the back panel to make the electrical connection The electrical connection is made on the terminal strip in the junction box inside the mac...

Страница 5: ...bin drain a 5 8 plastic tube Install rigid tubing between the machine and the building drain Route the drains separately to the building drain Water supply Connect cold potable water to the machine A...

Страница 6: ...dispenser The flange of the dispenser base fits in the slots in the sink extension base 10 Secure the sink extension base to the dispenser with 3 screws on each side 11 Return the dispenser to an upri...

Страница 7: ...3 Drill out the holes as marked in the illustration in the back of the frame with a 3 16 drill bit 4 Place top hanger bracket on the inside of the frame and fasten to the frame with the four screws r...

Страница 8: ...er about 15 seconds the machine should start 6 Let the machine operate listen for any unusual noises If needed reposition tubing panels to eliminate vibration After the unit has been operating for abo...

Страница 9: ...ontainer below the spout Note The water is NOT cooled it is the same temperature as the building supply water Daily Maintenance Pour hot water into the sink to flush out any debris or build up Wipe th...

Страница 10: ...at the top and has a spout at the bottom There is a rotating ice vane inside the bin that causes the ice to be swept over the spout and dispensed The vane is rotated by a gear motor at the top of the...

Страница 11: ...low pressure cause the refrigerant to evaporate and absorb heat from the metal walls of the evaporator After the refrigerant has flowed thru the evaporator it goes back to the compressor thru the suct...

Страница 12: ...the evaporator there is a water seal This seal is the type that has a rotating half and a stationary half The area where the two seals touch are smooth flat surfaces When the auger is installed in the...

Страница 13: ...sensor will send a signal to the control board to shut down the machine Refrigeration The refrigeration system uses a hermetic compressor specifically designed for R 134a forced draft air cooled conde...

Страница 14: ...the evaporator and then The auger motor no longer receives power from the circuit board and the auger motor stops After a 6 minute delay If the ice level sensor is clear bin empty for more than 15 sec...

Страница 15: ...sanitizing solution may be obtained by mixing 1 ounce of household bleach with 2 gallons of clean warm 95o F 115o F water 13 Unplug or disconnect electrical power 14 Remove bin top pour in warm potab...

Страница 16: ...clean with sanitizer 4 The splash panel requires special attention to clean it Push and release the Cleaning Switch located to the left of the ice spout This disables the Touch Free Sensor so the spla...

Страница 17: ...he water supply 3 Remove top panel 4 Remove right side panel 5 Drain the evaporator and reservoir 6 Remove foam cap on top of evaporator 7 Remove 2 permagum plugs from the side of the evaporator 8 Rem...

Страница 18: ...nt to come into contact with the face of the seal 4 Wash the stationary half the water seal with water Slip it up into the bottom of the evaporator until the bottom of the seal is inside the evaporato...

Страница 19: ...The water level sensor may not shut the ice machine off when the reservoir goes dry if there is a film of mineral scale on the probe tip 1 Remove the top panel 2 Remove the reservoir cover 3 Pull the...

Страница 20: ...ystem Ice in bin but will not dispense Drive motor does not turn Vend system does not work Check replace vend system Check that cleaning switch has been released Dispense motor open Check replace disp...

Страница 21: ...eplace solenoid Vend system does not work Check replace vend system Water turned off Restore water supply Water drips from spout Melting ice in chute Some water dripping is normal Water solenoid leaks...

Страница 22: ...6 minute off delay start To prevent short cycling the machine will not restart after any shut off excpet power to the board until 6 minutes have passed 5 Off Timer ON Unit cycling off Too much curren...

Страница 23: ...es or dirty eyes Clean and or adjust as needed To check the electrical system first check the lights on the circuit board 1 Remove the top panel 2 Remove the right side panel 3 Remove the control box...

Страница 24: ...rive gear motor to the bin top 6 Pull gear motor off the bin top 7 Unscrew the output shaft extension from the gear motor 8 Remove screws holding the mounting bracket to the gear motor 9 Reverse to re...

Страница 25: ...ir and lift the valve out of the reservoir tank 6 Replace with a new valve or replace the valve plunger Valve Plunger 1 After the valve has been removed from the reservoir remove the nut holding the v...

Страница 26: ...bottom of the auger and force the auger up Do NOT damage the splines of the auger or the auger will have to be replaced If the auger is frozen to the bottom bearing do not force the bottom bearing thr...

Страница 27: ...the water seal with water Slip it up into the bottom of the evaporator until the bottom of the seal is inside the evaporator about 1 4 5 Push the bottom bearing against the water seal until the bottom...

Страница 28: ...valves must be in the closed position before the hose caps are removed Do not remove the hose caps before checking the position of the valve Use a 3 16 allen wrench to open and close the valve As wit...

Страница 29: ...ding the gear reducer to the cabinet frame 12 Trace auger drive motor wires back to the control box 13 Disconnect the drive motor wires from the relay on the circuit board 14 Pull the wires back to th...

Страница 30: ...a relay on the circuit board 2 Disconnect the auger motor s wires and pull them back to the auger drive motor 3 Lift the auger motor windings off the gear reducer If the rotor needs to be removed 1 R...

Отзывы: