Capillary Tube

Bin Thermostat

Bracket

Fasten Cabinets

Together At Back

With Straps &

Screws.

Routing Hole

Stacking

Installation: Ice Storage Bin

Assembly:

1. Attach the legs, or optional casters, onto the ice
storage bin. Units that are stacked should only use
legs, not casters.

2. Be sure that the top edge of the bin has a good
gasket on it.

3. Place the ice machine onto the storage bin.

4. Line up the ice machine, check that there is a
good seal between the ice machine and the
storage bin.

5. If on a Scotsman bin, attach the ice machine to
the bin using the straps and bolts shipped with the
ice machine. Drill two 1/8" holes in the back of the
bin and secure with sheet metal screws provided.
If on another brand bin, follow the directions
included with that bin.

Bin Thermostat Installation:

1. Remove thermostat bracket from package.

2. Attach the bin thermostat bracket to the bottom
of the ice machine using the thumb screws
provided. There are pre-drilled and tapped holes
located just to the right of the cube drop area.

3. Locate and uncoil a portion of the
bin thermostat capillary tube. Route
the end of the capillary tube into the
plastic tube in the base of the ice
machine (next to the compressor) and
through the bin thermostat bracket.

Stacking:

This machine will stack onto any SLC300, 400 or
SLE400R. Note: Do not use casters when
stacking. Note: One condenser per remote unit.

1. Remove and discard the left top panel from the
lower unit.

2. Remove knock out plug from top right panel.

3. Place gasket material around the top of the
bottom unit’s cabinet & evaporator compartment.

4. Carefully lift the uncrated top unit onto the
bottom unit. Use of a mechanical lift is
recommended for this step.

5. Align the two ice maker cabinets.

6. Secure the top unit to the bottom one with the
hardware and straps shipped with the upper
machine.

7. Locate and uncoil all of the bin thermostat
capillary tube.

8. Route the bin thermostat capillary tube from the
upper unit, through the hole in the base, through
the lower unit and into the bin thermostat bracket.
Discard upper unit bracket.

Bin Thermostat

Installation

Thermostat

Capillary Tube

Bin Thermostat

Bracket

Note: SLB150: Use thermostat

bracket packed with that bin.

SLE400R

January 1995

Page 5

Содержание SLE400R

Страница 1: ...warning symbol where it appears in this manual It is an alert for important safety information on a hazard that might cause serious injury Keep this manual for future reference This manual was printe...

Страница 2: ...s used to determine wire size and type per the National Electric Code Note Do not connect this refrigeration system to a used condenser circuit Only the condenser and line set specified for this machi...

Страница 3: ...factured with the highest regard for safety and performance They meet or exceed the standards of UL NSF and CSA Scotsman assumes no liability or responsibility of any kind for products manufactured by...

Страница 4: ...itions Have the water tested Acidic water or alkaline water will both cause corrosion Dissolved solids cannot be filtered out Softened water is not recommended Never use de ionized water Reverse osmos...

Страница 5: ...ea 3 Locate and uncoil a portion of the bin thermostat capillary tube Route the end of the capillary tube into the plastic tube in the base of the ice machine next to the compressor and through the bi...

Страница 6: ...nd of the capillary tube thru the tube watch the capillary as it comes out of the base line it up with the inlet hole of the thermostat bracket and push it into the hole Move the cabinet of the ice ma...

Страница 7: ...kit place the stainless steel adapter onto the top of the dispenser Follow all directions included with the kit 8 After the ice machine has been placed on the dispenser remove the front panel and unc...

Страница 8: ...igid and meet local code Traps in the bin drain line without vents ahead of them will cause poor draining The bin drain must be vented if there is a long horizontal run 5 or more The reservoir drain m...

Страница 9: ...condenser and to the ice machine Be certain that there is no metal to metal or tight tube to tube contact between the liquid and discharge lines Coil excess tubing inside the building in a horizontal...

Страница 10: ...ections to the wires in the junction box A ground screw is provided in the junction box Follow All Local Codes This Unit Must Be Grounded Usually a licensed electrician will be required to connect the...

Страница 11: ...l 8 Is the ice machine connected to a 230 volt electrical power supply and is the ice machine the only load on that circuit 9 Has all of the shipping material been removed from the inside of the cabin...

Страница 12: ...e control adjustment ICE OFF WASH switch Control box Ice Thickness Control ICE OFF WASH Switch Bin Thermostat Water Distributor Pan Bin Thermostat Bracket Water Inlet Valve Strainer Water Pump Control...

Страница 13: ...he ICE OFF WASH switch to ON 11 The remote fan motor will begin to turn and warm air will be discharged from the top of the remote condenser 12 The water temperature in the reservoir will soon be 320...

Страница 14: ...motor and the pump motor The Harvest Termination Thermostat is closed to NC but there is no power thru it The ice size thermostat heater is on and the compressor contactor coil is energized Harvest In...

Страница 15: ...r 1 Mix the bleach and water using the ratio of two ounces of bleach to two gallons of water 2 Wipe all interior surfaces of the ice storage bin with the bleach and water 3 Allow to air dry To Remove...

Страница 16: ...e 17 Remove the water distributor pan 18 Mix a sanitizer solution of 1 ounce of household bleach to 2 gallons of warm 95o F 115o F water 19 Wash the splash guard and the water distributor pan with the...

Страница 17: ...mote condenser Water Water flows into the ice machine from its inlet connection at the back of the cabinet through the inlet water valve and into the reservoir The water in the reservoir is pumped up...

Страница 18: ...Discharge Pressure In Harvest 130 150 PSIG Typical Compressor Amp Draw 4 5 during freeze cycle 5 6 during the harvest cycle Compressor Copeland RS64C1E CAV 214 Thermostatic Expansion Valve Superheat i...

Страница 19: ...ive TXV or compressor Unit off due to low pressure pump down control open Check liquid line valve coil for power and or continuity No ice is made compressor is operating No water due to water turned o...

Страница 20: ...ess than 550 F Warm up air or move machine Lack of heat during harvest due to water flowing thru water cooled condenser Replace water regulating valve Lack of heat during harvest due to lack of refrig...

Страница 21: ...Replace valve if temps are nearly equal Compressor inefficient Check replace compressor Cubes are wrong size shape Ice size thermostat not adjusted properly Adjust ice size thermostat use gauge shipp...

Страница 22: ...he ice size thermostat with the proper part number following the above steps from 9 1 Primary Resistor Heater 1 Disconnect electrical power 2 Disconnect the primary resistor s yellow wire from termina...

Страница 23: ...rge hose from pump discharge port 8 Remove pump from ice machine 9 Reverse above steps to replace Inlet Water Valve The valve may plug up from minerals in the water and should then be cleaned rather t...

Страница 24: ...iquid line dryer is required Polyol ester oil absorbs water very easily and when the system is opened for service it must be re sealed as soon as possible 15 minutes maximum Special leak detection equ...

Отзывы: