Service Diagnosis:

SYMPTOM

POSSIBLE CAUSE

PROBABLE FIX

Ice is made, but will not harvest

Will not harvest due to hot gas
valve not opening.

Check for voltage to coil in
harvest, if there is voltage replace
hot gas valve

Slow/incomplete harvest due to
hot gas valve not fully open.

Check low side pressure in
harvest, replace hot gas valve if
too low with correct ref. charge.

Makes ice, but very little

High discharge pressure, due to
dirty condenser; faulty fan motor;

Check for causes of high
discharge pressure and correct.

Inlet water temperatures and
room ambient very high

Advise user, suggest additional
room cooling.

Long freeze cycle due to hot gas
valve leaking thru.

Check temperature of tubes to
and from hot gas valve; there
should be a temperature drop
across the valve in the freeze
cycle. Replace valve if temps are
nearly equal.

Compressor inefficient

Check/replace compressor

Cubes are wrong size/shape

Ice size thermostat not adjusted
properly

Adjust ice size thermostat; use
gauge shipped with machine

Freeze cycle too short due to
heater open

Check/replace heater on ice size
thermostat probe tube.

Water system is restricted with
minerals

Clean water system with
Scotsman Ice Machine Cleaner

Ice thickness probe tube covered
with minerals

Clean tube with ice machine
cleaner

Not enough water

Check water supply pressure

Check water supply for restrictions

Too much superheat

Check superheat, replace TXV if
too high.

Check hot gas valve for leak-thru;
replace if leaks thru.

Ice fused together in bin

Ice in bin too long

Advise user to pour water on ice
to ease removal

Too many minerals in water

Suggest water treatment to user.

Unit does not shut off

Bin control will not close

Check & replace bin control

K1 relay coil open

Check & replace K1 relay

SLE400R

January 1995

Page 21

Содержание SLE400R

Страница 1: ...warning symbol where it appears in this manual It is an alert for important safety information on a hazard that might cause serious injury Keep this manual for future reference This manual was printe...

Страница 2: ...s used to determine wire size and type per the National Electric Code Note Do not connect this refrigeration system to a used condenser circuit Only the condenser and line set specified for this machi...

Страница 3: ...factured with the highest regard for safety and performance They meet or exceed the standards of UL NSF and CSA Scotsman assumes no liability or responsibility of any kind for products manufactured by...

Страница 4: ...itions Have the water tested Acidic water or alkaline water will both cause corrosion Dissolved solids cannot be filtered out Softened water is not recommended Never use de ionized water Reverse osmos...

Страница 5: ...ea 3 Locate and uncoil a portion of the bin thermostat capillary tube Route the end of the capillary tube into the plastic tube in the base of the ice machine next to the compressor and through the bi...

Страница 6: ...nd of the capillary tube thru the tube watch the capillary as it comes out of the base line it up with the inlet hole of the thermostat bracket and push it into the hole Move the cabinet of the ice ma...

Страница 7: ...kit place the stainless steel adapter onto the top of the dispenser Follow all directions included with the kit 8 After the ice machine has been placed on the dispenser remove the front panel and unc...

Страница 8: ...igid and meet local code Traps in the bin drain line without vents ahead of them will cause poor draining The bin drain must be vented if there is a long horizontal run 5 or more The reservoir drain m...

Страница 9: ...condenser and to the ice machine Be certain that there is no metal to metal or tight tube to tube contact between the liquid and discharge lines Coil excess tubing inside the building in a horizontal...

Страница 10: ...ections to the wires in the junction box A ground screw is provided in the junction box Follow All Local Codes This Unit Must Be Grounded Usually a licensed electrician will be required to connect the...

Страница 11: ...l 8 Is the ice machine connected to a 230 volt electrical power supply and is the ice machine the only load on that circuit 9 Has all of the shipping material been removed from the inside of the cabin...

Страница 12: ...e control adjustment ICE OFF WASH switch Control box Ice Thickness Control ICE OFF WASH Switch Bin Thermostat Water Distributor Pan Bin Thermostat Bracket Water Inlet Valve Strainer Water Pump Control...

Страница 13: ...he ICE OFF WASH switch to ON 11 The remote fan motor will begin to turn and warm air will be discharged from the top of the remote condenser 12 The water temperature in the reservoir will soon be 320...

Страница 14: ...motor and the pump motor The Harvest Termination Thermostat is closed to NC but there is no power thru it The ice size thermostat heater is on and the compressor contactor coil is energized Harvest In...

Страница 15: ...r 1 Mix the bleach and water using the ratio of two ounces of bleach to two gallons of water 2 Wipe all interior surfaces of the ice storage bin with the bleach and water 3 Allow to air dry To Remove...

Страница 16: ...e 17 Remove the water distributor pan 18 Mix a sanitizer solution of 1 ounce of household bleach to 2 gallons of warm 95o F 115o F water 19 Wash the splash guard and the water distributor pan with the...

Страница 17: ...mote condenser Water Water flows into the ice machine from its inlet connection at the back of the cabinet through the inlet water valve and into the reservoir The water in the reservoir is pumped up...

Страница 18: ...Discharge Pressure In Harvest 130 150 PSIG Typical Compressor Amp Draw 4 5 during freeze cycle 5 6 during the harvest cycle Compressor Copeland RS64C1E CAV 214 Thermostatic Expansion Valve Superheat i...

Страница 19: ...ive TXV or compressor Unit off due to low pressure pump down control open Check liquid line valve coil for power and or continuity No ice is made compressor is operating No water due to water turned o...

Страница 20: ...ess than 550 F Warm up air or move machine Lack of heat during harvest due to water flowing thru water cooled condenser Replace water regulating valve Lack of heat during harvest due to lack of refrig...

Страница 21: ...Replace valve if temps are nearly equal Compressor inefficient Check replace compressor Cubes are wrong size shape Ice size thermostat not adjusted properly Adjust ice size thermostat use gauge shipp...

Страница 22: ...he ice size thermostat with the proper part number following the above steps from 9 1 Primary Resistor Heater 1 Disconnect electrical power 2 Disconnect the primary resistor s yellow wire from termina...

Страница 23: ...rge hose from pump discharge port 8 Remove pump from ice machine 9 Reverse above steps to replace Inlet Water Valve The valve may plug up from minerals in the water and should then be cleaned rather t...

Страница 24: ...iquid line dryer is required Polyol ester oil absorbs water very easily and when the system is opened for service it must be re sealed as soon as possible 15 minutes maximum Special leak detection equ...

Отзывы: