Scotsman SLE400R Скачать руководство пользователя страница 1

Introduction

To the owner or user: This service manual is
intended to provide you, and the maintenance or
service technician, with the information needed to
install, start up, clean, maintain and repair this
product.

The SLE400R is an ice machine that produces
cubed ice on 6 vertical cube freezing surfaces.

When harvested, the cubes fall individually into the
ice storage bin. The SLE400R automatically
maintains the level of ice by turning on when the
ice level falls, and switches off when the bin is full.

The refrigeration system uses R-404A as the
refrigerant.

Parts lists and wiring diagrams are located in the
center of this manual, printed on yellow paper.

Note the warning symbol where it
appears in this manual. It is an alert for
important safety information on a hazard
that might cause serious injury.

Keep this manual for future reference.

This manual was printed on recycled paper.

Table of Contents

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

For The Installer: Environmental Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

Installation: Ice Storage Bin

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Installation: SLD150 Hotel Dispenser

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6

Installation: Scotsman IS or RS Dispenser . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

8

Installation: Remote Condenser System . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

Installation

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

After Utility Connections

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

Component Location

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Initial Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Maintenance, Cleaning and Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

Cleaning: Ice Machine Water System

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

How It Works: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

17

Technical Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

18

Service Diagnosis:

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

19

Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

22

Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

23

Removal and Replacement: Refrigeration System . . . . . . . . . . . . . . . . . . . . . . . .

24

SLE400R

January 1995

Page 1

Содержание SLE400R

Страница 1: ...warning symbol where it appears in this manual It is an alert for important safety information on a hazard that might cause serious injury Keep this manual for future reference This manual was printe...

Страница 2: ...s used to determine wire size and type per the National Electric Code Note Do not connect this refrigeration system to a used condenser circuit Only the condenser and line set specified for this machi...

Страница 3: ...factured with the highest regard for safety and performance They meet or exceed the standards of UL NSF and CSA Scotsman assumes no liability or responsibility of any kind for products manufactured by...

Страница 4: ...itions Have the water tested Acidic water or alkaline water will both cause corrosion Dissolved solids cannot be filtered out Softened water is not recommended Never use de ionized water Reverse osmos...

Страница 5: ...ea 3 Locate and uncoil a portion of the bin thermostat capillary tube Route the end of the capillary tube into the plastic tube in the base of the ice machine next to the compressor and through the bi...

Страница 6: ...nd of the capillary tube thru the tube watch the capillary as it comes out of the base line it up with the inlet hole of the thermostat bracket and push it into the hole Move the cabinet of the ice ma...

Страница 7: ...kit place the stainless steel adapter onto the top of the dispenser Follow all directions included with the kit 8 After the ice machine has been placed on the dispenser remove the front panel and unc...

Страница 8: ...igid and meet local code Traps in the bin drain line without vents ahead of them will cause poor draining The bin drain must be vented if there is a long horizontal run 5 or more The reservoir drain m...

Страница 9: ...condenser and to the ice machine Be certain that there is no metal to metal or tight tube to tube contact between the liquid and discharge lines Coil excess tubing inside the building in a horizontal...

Страница 10: ...ections to the wires in the junction box A ground screw is provided in the junction box Follow All Local Codes This Unit Must Be Grounded Usually a licensed electrician will be required to connect the...

Страница 11: ...l 8 Is the ice machine connected to a 230 volt electrical power supply and is the ice machine the only load on that circuit 9 Has all of the shipping material been removed from the inside of the cabin...

Страница 12: ...e control adjustment ICE OFF WASH switch Control box Ice Thickness Control ICE OFF WASH Switch Bin Thermostat Water Distributor Pan Bin Thermostat Bracket Water Inlet Valve Strainer Water Pump Control...

Страница 13: ...he ICE OFF WASH switch to ON 11 The remote fan motor will begin to turn and warm air will be discharged from the top of the remote condenser 12 The water temperature in the reservoir will soon be 320...

Страница 14: ...motor and the pump motor The Harvest Termination Thermostat is closed to NC but there is no power thru it The ice size thermostat heater is on and the compressor contactor coil is energized Harvest In...

Страница 15: ...r 1 Mix the bleach and water using the ratio of two ounces of bleach to two gallons of water 2 Wipe all interior surfaces of the ice storage bin with the bleach and water 3 Allow to air dry To Remove...

Страница 16: ...e 17 Remove the water distributor pan 18 Mix a sanitizer solution of 1 ounce of household bleach to 2 gallons of warm 95o F 115o F water 19 Wash the splash guard and the water distributor pan with the...

Страница 17: ...mote condenser Water Water flows into the ice machine from its inlet connection at the back of the cabinet through the inlet water valve and into the reservoir The water in the reservoir is pumped up...

Страница 18: ...Discharge Pressure In Harvest 130 150 PSIG Typical Compressor Amp Draw 4 5 during freeze cycle 5 6 during the harvest cycle Compressor Copeland RS64C1E CAV 214 Thermostatic Expansion Valve Superheat i...

Страница 19: ...ive TXV or compressor Unit off due to low pressure pump down control open Check liquid line valve coil for power and or continuity No ice is made compressor is operating No water due to water turned o...

Страница 20: ...ess than 550 F Warm up air or move machine Lack of heat during harvest due to water flowing thru water cooled condenser Replace water regulating valve Lack of heat during harvest due to lack of refrig...

Страница 21: ...Replace valve if temps are nearly equal Compressor inefficient Check replace compressor Cubes are wrong size shape Ice size thermostat not adjusted properly Adjust ice size thermostat use gauge shipp...

Страница 22: ...he ice size thermostat with the proper part number following the above steps from 9 1 Primary Resistor Heater 1 Disconnect electrical power 2 Disconnect the primary resistor s yellow wire from termina...

Страница 23: ...rge hose from pump discharge port 8 Remove pump from ice machine 9 Reverse above steps to replace Inlet Water Valve The valve may plug up from minerals in the water and should then be cleaned rather t...

Страница 24: ...iquid line dryer is required Polyol ester oil absorbs water very easily and when the system is opened for service it must be re sealed as soon as possible 15 minutes maximum Special leak detection equ...