INSTRUCTIONS FOR USING TESTER
(Optional, order part no. A33942-001)
(These instructions assume that the unit will not run, and prior investigation of electric power, controls, and
mechanical parts indicates that the electronic circuit may be at fault.)
Bin Control
Note: All testing is done with the
electrical power on, the master switch on, and all
reset switches "reset" .
1. Unplug "photo trans" and "LED" connectors
from the circuit board.
2. Plug "photo trans" and "LED" connectors from
the tester into the circuit board.
a. Move the "bin full" switch on the tester to Full.
The light on the tester should be ON.
If the light on the tester is not on, the circuit board
should be replaced.
b. If the light on the tester IS on, move the "bin
full" switch to Bin Empty. The light on the tester
should go OFF, and the Bin Empty light on the
circuit board should go ON.
If the machine still does not run, replace the ice
level sensors.
ELECTRONIC CONTROL TESTER
PHOTO TRANS
LED
LIGHT
GOES ON
SWITCH TO
"FULL"
LIGHT GOES ON
SWITCH TO
"BIN EMPTY"
LIGHT
GOES OFF
Electrical shock hazard.
Electrical power can
cause personal injury.
Disconnect electrical
power before beginning.
NME1250R
August 1993
Page 35