5. Clean the air cooled condenser.
The air flow on this model is from front to back, so
the inside of the machine will have to be available
to clean the air cooled condenser. Use a vacuum
cleaner or coil cleaner if needed. Do NOT use a
wire brush.
A. Disconnect electrical power, and remove the
filter. The filter may be cleaned or replaced.
B. Clean the condenser: the condenser may
appear to be clean on the surface, but it can still
be clogged internally. Check with a flash light from
the front to see if light can be seen though the
condenser fins. Reverse to reassemble.
MAINTENANCE: Air Cooled
1. REMOVE TOP PANEL
2. REMOVE TWO SCREWS & UNPLUG FAN MOTORS.
3. PULL FAN MOTOR ASSEMBLY UP AND OUT
4. CLEAN CONDENSER FINS.
TO GAIN ACCESS TO CONDENSER SURFACE:
Electrical shock hazard.
Electrical shock can
cause personal injury.
Disconnect power before
beginning to service
components.
NM952
August 1993