background image

ELECTRICAL SEQUENCE

There are 7 indicator lights on the control board:

·

WTR-OK.

Water OK. Normal = Glowing. Glows

when there is water in the reservoir.

·

PWR-OK.

Power OK. Normal = Glowing. Glows

when the control board has power

and

is

functional.

·

Service.

Normally Off.

·

Freeze.

Normally Glowing when making ice.

·

Bin Full.

Normally Off when making ice.

·

LED1.

Normally Glowing when making ice.

·

LED3.

Normally Glowing when making ice.

If the machine is switched off at the mode switch,

but is otherwise ready to go, switching the mode

switch to ON does the following:

·

The PWR-OK light glows.

·

If there is water in the reservoir the WTR-OK

light glows.

·

After 10 seconds the Freeze, LED1 and LED3

lights glow and the machine starts up.

Start Up:

·

The compressor relay and auger motor relay

become energized, connecting power to the

windings of the auger motor and contactor coil.

·

The contactor is energized, connecting power to

the compressor, and the compressor starts.

·

During normal operation ice passes between

the ice level sensors but only interupts their

infrared beam momentarily. The bin full light

remains off and the machine stays on until ice

builds up in the bin and blocks the path between

the sensors for 6 seconds or longer. When that

occurs the bin full light glows and the machine

shuts down.

Ice Vending

When the glass filler lever is pushed in the vend

switch closes connecting power to the ice chute

door solenoid and agitator drive motor.

Optional Portion Control:

The portion control

module will power the agitator drive motor for a set

length of time. The amount of time is controlled by

the setting of the portion control knob,.

Holding the glass filler lever in will not cause

additional dispensing, unless the portion control is

set for continuous dispensing. Releasing and

re-pushing the glass filler lever will repeat the

dispense cycle.

Shut Down:

·

The compressor relay opens, LED1 goes out.

·

The compressor contactor opens

·

The compressor stops

·

The auger motor stays on for 1 more minute,

clearing out ice in the evaporator, and then

·

The auger motor relay opens, LED3 goes out

and the auger motor stops.

The compressor will not restart until 2 minutes or

more have passed after the last shut down. If the

path between the ice level sensors remains clear

for more than 10 seconds the machine will restart.

Another purpose of the control board is to turn the

machine off when necessary:

·

When the water level in the reservoir falls below

the water level sensor’s tip, the WTR-OK light

goes out and the machine shuts down. When

water refills the reservoir the WTR-OK light

glows and the machine starts up again.

·

If the auger drive motor current becomes

excessive the compressor and auger drive

motor will be switched Off and the Service light

will blink. The control board will restart the auger

drive motor in 4 minutes. If during the first 60

seconds after restart the auger motor current

stays within limits, the compressor is restarted

and the machine returns to normal operation. If

the current is excessive within 60 seconds after

the restart, the process will be repeated once

more. If after that try the current is still

excessive the machine shuts down and must be

manually reset. The service light will then be

glowing continuously.

To Reset: Disconnect and reconnect power to

the ice machine.

Separate from the circuit board:

·

If the high pressure cut out switch opens the

machine stops immediately. It automatically

resets when the pressure drops below its cut in

point.

·

If the low pressure cut out switch opens the

machine will stop immediately. It automatically

resets when the pressure rises over its cut in

point.

·

The mode switch is the manual control for the

complete machine, but it is not a service

disconnect.

NDE754

March 2000

Page 11

Содержание NDE754

Страница 1: ...THE INSTALLER Specifications Page 2 FOR THE INSTALLER Page 3 FOR THE PLUMBER Page 4 FOR THE ELECTRICIAN Page 5 FOR THE INSTALLER Final Check List Page 6 INITIAL START UP Page 7 COMPONENT DESCRIPTION P...

Страница 2: ...ons An ice machine is a food manufacturing plant it takes in a raw material water and turns it into a food product ice The purity of the water is very important in obtaining pure ice and in maximizing...

Страница 3: ...ers so that the stand does not rock Counter Top or Machine Stand Installation The base of the icemaker dispenser must be sealed to the object it rests upon Food grade silastic sealant such as Scotsman...

Страница 4: ...t to the 3 8 FPT condenser inlet at the back of the cabinet The water pressure to all lines must always be above 20 psig and below 120 psig Drains Air Cooled Models Connect a drain tube to the one 3 4...

Страница 5: ...ity The machine requires a solid chassis to earth ground wire The ice maker should be connected to its own electrical circuit so it would be individually fused Voltage variation must remain within des...

Страница 6: ...checked and compared to nameplate requirements 3 Have all of the plumbing connections been made and checked for leaks 4 Has the machine been leveled 5 Is there a minimum of 6 inches of clearance at t...

Страница 7: ...sure will depend upon air and water temperatures but should be between 200 PSIG and 300 PSIG Water cooled discharge pressure should be about 245 PSIG If needed adjust the water regulating valve The ab...

Страница 8: ...oint 15 psig Drain Tube When uncapped and lowered drains the evaporator Condenser Air or water cooled where the heat removed in ice making is discharged Ice Storage Bin Assembly A plastic lined insula...

Страница 9: ...he two seal faces meet Ice Sweep A plastic cap with fingers It revolves with the auger to sweep the ice into the ice chute Breaker Where the ice is compressed and much of the extra water is squeezed o...

Страница 10: ...vel and water level The relays are for the gear motor with a built in time delay to clear the evaporator of ice when the unit turns off and for the compressor Mode Switch Manual control for the machin...

Страница 11: ...e pushing the glass filler lever will repeat the dispense cycle Shut Down The compressor relay opens LED1 goes out The compressor contactor opens The compressor stops The auger motor stays on for 1 mo...

Страница 12: ...water regulating valve then to the water cooled condenser and down the drain The water dispensing station adds an additional water circuit When the water station glass filler lever is pushed a switch...

Страница 13: ...depending upon the temperature of the evaporator warmer evaporators get more refrigerant and colder evaporators get less At the evaporator the refrigerant enters an area of relatively low pressure whe...

Страница 14: ...nected to the agitator drive motor Dispensing takes place when the agitator sweeps the ice through the ice dispensing chute ice will continue to discharge out this chute as long as the agitator is tur...

Страница 15: ...15 minutes then switch the master switch to ON 9 As the ice maker begins to use water from the reservoir continue to add more cleaning solution to maintain a full reservoir 10 After all of the cleani...

Страница 16: ...nd the tip wiped clean of mineral build up 2 The bin control uses devices that sense light therefore they must be kept clean enough so that they can see At least twice a year remove the bin control se...

Страница 17: ...e action of the bearing It should rotate smoothly To remove the breaker remove the lower ice chute then take out all four allen head cap screws and pull the breaker off the auger and evaporator If the...

Страница 18: ...VAL AND REPLACEMENT Disconnect electrical power and shut off the water supply Use care when removing the auger it has sharp edges 1 To remove the auger remove the front and top panels 2 Drain evaporat...

Страница 19: ...d in evaporator Low pressure control open Auger not turning due to motor failure auger relay failure on circuit board or gears stripped Check drive train TXV restricted or not metering Check bulb temp...

Страница 20: ...essor is not check the compressor contactor coil If it is on the ice sensors may be blocked Remove them and check for mineral scale Scotsman s test box can also be used to determine if the ice sensors...

Страница 21: ...el sensor probe 8 Remove mounting screws from reservoir bracket and remove reservoir from icemaker 9 Reverse to reassemble BIN CONTROLS Ice Level Sensors 1 Disconnect electrical power 2 Remove front p...

Страница 22: ...h spots and damage a The bearing is pressed into the breaker to remove the bearing and replace it an arbor press is needed b Replace lower seals before installing new bearing in breaker Note seals mus...

Страница 23: ...rews holding breaker to evaporator d Lift up remove breaker from evaporator e If the auger is stuck use a slide hammer type puller to pull on the auger at the threaded hole The size of that hole is 5...

Страница 24: ...he grove for the snap ring 2 Replace the snap ring and pull the water seal down against it 3 The part of the water seal that rotates with the auger must also be replaced Remove the old part from the a...

Страница 25: ...new drier in the liquid line 7 Evacuate the system until dehydrated then weigh in the nameplate charge Check for leaks 8 Install auger breaker breaker bearing assembly and ice discharge chute in rever...

Страница 26: ...ne if the oil is If there is evidence of water in the oil rusty bearings and gears the oil having a creamy white appearance oil level too high carefully inspect the bearings and gears If in doubt abou...

Страница 27: ...glass and or a restricting device such as a Charge Faster installed in it for metering liquid into the low side of the system 1 After a thorough evacuation shut off the manifold valves and switch off...

Отзывы: