A. To Remove the Freezer Assembly:
1. Remove screws and left and right side

rear panels.

2. Refer to procedure IV-12 and remove the

Spout Assembly, Ice Breaker and Auger.

3. Remove Corbin clamp and Tygon tube

from the Freezer Assembly that connects to the

Water Reservoir Assembly.

4. Perform operation at steps 2-3-4-5 at

procedure IV-10.

5. Disconnect suction line joint from the

freezer.

6. Unsolder the refrigerant inlet line at the

freezer.

7. Remove screws that secure bracket of

freezer to the left side of chassis.

8. Remove screws, lock washers and

washers which attach the bottom of the Freezer

Assembly to the Adaptor on the Gear box.

9. Lift the Freezer Assembly up and off of

the Adaptor of Gear box.

NOTE

:  Throughly evacuate the System to

remove moisture and non - condensables.

B. To replace the Freezer Assembly, reverse

the removal procedure.

7.

REMOVAL AND REPLACEMENT OF THE

WATER RESERVOIR ASSEMBLY

A. To remove the Water Reservoir

Assembly:

1. Remove screws and the left Panel and

the Top Panel. Close the Water Supply.

Drain water reservoir and freezer assy.

Using the drain tube attached to the freezer

water inlet.

NOTE

:  Be prepared with container or rags,

to catch water left in lines, when lines are

disconnected in next steps, to prevent

draining water on parts, components,

electrical lines, etc.

2. Disconnect the water inlet tube from the

Water Reservoir Assembly.

3. Remove two corbin clamps and two

tubes from the bottom of the water reservoir assy

and damp all water in them by bending them

down in a pail.

4. Unscrew and remove the screws that

secure the water reservoir bracket.

5.  Remove the Water Reservoir Assembly,

from the mounting bracket.

B. To replace the Water Reservoir Assembly,

reverse the removal procedure.

NOTE

:  Check that the installed replacement

Water Reservoir Assembly float moves freely.

8

REMOVAL AND REPLACEMENT OF THE

DRIVE MOTOR

A. To remove the drive motor assembly:
1. Remove screws and front, and left side

panels.

2. Disconnect wire leads to motor.
3. Remove four hex head bolts, lockwashers

and washer which attach the motor to the gear

reducer.

4. Remove the drive motor out of the gear

reducer.

B. To replace the drive Motor reverse the

removal procedure.

9. REMOVAL AND REPLACEMENT OF

GEAR BOX

A. Remove screws and all service panels.
1. Remove four nuts and washers which

hold the gear box adaptor to the evaporator

assembly.

2. Unloose and remove screws securing

upper evaporator bracket to left side chassis.

3. With a small hydraulic Hoist raise the

evaporator assembly to facilitate removal of entire

gear box.

4. Unloose and remove four nuts holding

the gear box to unit base. The gear box is now

loose and can be removed. Do not tilt to avoid oil

spillage.

NOTE

:  Gear box is supplied with the drive

motor already in place.

B. To remount Gear Box assembly reverse the

removal procedure taking care to position correctly

the output shaft with its keys well in shape.

Содержание MF 88

Страница 1: ...2 93960 1 Aut Sel Telefax 39 02 93550500 Direct Line to Service Parts Phone 39 02 93960350 Fax 39 02 93540449 Website www scotsman ice it E Mail scotsman europe scotsman it ISO 9001 Cert n 0080 SERVIC...

Страница 2: ...Page 2 Page 2 TO BE USED JUST BY THE INSTALLER...

Страница 3: ...om Unpacking and iInspection Location and levelling Electrical connection Water supply and drain connection Final check list OPERATING INSTRUCTIONS Pre start inspection Start up PRINCIPLES OF OPERATIO...

Страница 4: ...n exceeding these limitations constitutes misuse under the terms of Scotsman Manufacturer s Limited Warranty resulting in a loss of warranty coverage We reserve the right to make product improvement a...

Страница 5: ...IDTH 540 mm DEPTH 780 mm NET WEIGHT 250 Kg MF MFN 88 SPLIT MACHINE SPECIFICATIONS Basic electrical Refrigerant Drive Motor Ice Type 230 50 3N 2 65 Amps 1410 rpm 7050 Kcal hr R404a 8200 W 400 50 3N 5A...

Страница 6: ...he left to right anf front to rear direction INTRODUCTION This manual provides the specifications and the step by step procedures for the installation start up operation and maintenance and cleaning o...

Страница 7: ...at ice builds up in the chute Thermostat capillary tube is coiled behind the control box it must be routed to follow the ice chute or ice deflector and protrude for a certain extension beyond the ice...

Страница 8: ...ed of the Time Delay Relay KT1 blinking the liquid valve opens 3 After two or three minutes of unit operation observe that flaked ice begins to drop out in the ice spout 4 Let the system operate for a...

Страница 9: ...through the Ice breaker The flake ice into spout in diverted out through the ice discharge opening Once unit is electrically connected after 15 minutes starts the automatic and continuous icemaking pr...

Страница 10: ...is reduced to below 0 3 bar 4 PSI The switch will automatically restart the icemaking process when the water pressure is increased to 1 bar 14 PSI EPR valve Evaporator Pressure Regulating Valve this v...

Страница 11: ...set to cut out at 1 5 C and cut in at 4 C The Expansion Valveis FLICA mod AMVX 3 Press 3 bar Office 4 5 mm for R 404 A meters the refrigerant to the evaporator serpentine at 1 7 bar 25 PSI From s n 2...

Страница 12: ...screws in the corresponding holes and tighten WARNING Be sure the electrical power supply and the water supply are OFF before starting any of the following REMOVAL AND REPLACEMENT procedures as a prec...

Страница 13: ...or water seal should be removed by pulling out the bearing retainer from the bottom of freezer barrel You can heat the bearing retainer with a soft flame The bearing will drop out by itself 14 Remove...

Страница 14: ...m the Water Reservoir Assembly 3 Remove two corbin clamps and two tubes from the bottom of the water reservoir assy and damp all water in them by bending them down in a pail 4 Unscrew and remove the s...

Страница 15: ...emperature room temp 10 C 5th Warning light glows Wrong connection of the three Reverse two of them phase to the unit plug Short of one of the three phases Check for proper power supply 6th Warning li...

Страница 16: ...ice Surrounging air temperature Correct or move unit to cooled above 40 C 100 F location Under or over charge of Re charge with proper refrigerant amount Closed TEV Adjust valve for correc refrigerant...

Страница 17: ...electrical circuit of the MF MFN 88 The Wiring Diagrams in this Sections is Wiring diagram MF MFN 88 AS 400 50 3 N WARNING When conducting a conti nuity check of the MF MFN 88 1 Disconnect the main po...

Страница 18: ...Page 18 Page 18 WIRING DIAGRAM MF MFN 88...

Страница 19: ...Page 19 Page 19...

Страница 20: ...res about 70 which is hot to touch Check with Ammeter amps drawn and make sure they are in the limits of Drive motor windings 9 Check setting and function of all the pressure controls also make sure t...

Страница 21: ...e spout until the water reservoir is empty DO NOT allow the icemaker to operate with empty reservoir 9 Unplug again the unit 10 Flush out the remaining cleaning solution from freezer as per step 4 Was...