OPERATION: Refrigeration
Beginning at the compressor
, the refrigerant is
compressed into a high temperature gas. The
discharge line directs this gas to the condenser
and to the head pressure control At the
remote
condenser
the gas is cooled by air and it then
condenses into a liquid. This high pressure liquid
then goes through the liquid line to the liquid line
connection at the
head pressure control.
If the
head pressure is high enough the liquid refrigerant
will go through the valve and enter the
receiver.
From the receiver, the liquid refrigerant flows
through the
liquid line valve
and then to the
expansion valve.
The
thermostatic expansion valve
meters liquid
refrigerant into the
evaporator,
the volume of
liquid refrigerant depending upon the temperature
of the evaporator; warmer evaporators get more
refrigerant and colder evaporators get less. At the
evaporator, the refrigerant enters an area of
relatively low pressure, where it can easily “boil off”
or evaporate. As it evaporates, it absorbs heat
from the evaporator and whatever is in contact with
it (such as the water inside it). After the
evaporator, the refrigerant, now a low pressure
vapor, goes through the suction line back to
compressor
, where the cycle is repeated.
NME1254R & FME1504R
January 2000
Page 17
DETAIL OF HEAD
PRESSURE CONTROL
VALVE
LIQUID LINE
VALVE
COMPRESSOR
RECEIVER
HEAD
PRESSURE
CONTROL
VALVE
DISCHARGE
LINE
LIQUID LINE
REMOTE CONDENSER
THERMOSTATIC
EXPANSION
VALVE
EVAPORATOR