FOR THE PLUMBER
CONFORM TO ALL APPLICABLE CODES
Water Inlet
Connect a cold potable water supply
to the ice machine. Use 3/8" O.D.
copper tubing and connect it to the
3/8" male flare at the back of the
cabinet.
Install a hand valve near the machine
to control the water supply.
Drains
The cabinet has a ¾" FPT drain.
connection. The drain is at the back of
the cabinet, the drain line is of the
gravity type, and 1/4 inch per foot fall
is an acceptable pitch for the drain
tubing. There should be a vent at the
highest point of the drain line, and the
ideal drain receptacle would be a
trapped and vented floor drain. Use
only ¾" rigid tubing.
Storage Bin:
Install a
separate
gravity drain to the ice storage bin.
Insulation of this drain line is
recommended.
NME954R & FME1204R
January 2000
Page 9
Floor Drain
Vent Bin Drain
3/4" FPT
Vent Ice
Maker
Drain, 3/4"
FPT
Water Inlet
3/8" Male Flare
Field Supplied
Water Filter
Hand Shut
Off Valve
Connect To
Cold Water