FOR THE ELECTRICIAN
CONFORM TO ALL APPLICABLE CODES
Connect the electrical power to the ice machine
through the junction box at the back.
Check the nameplate (located on the back panel)
for the voltage requirements, and for the minimum
circuit ampacity. The machine requires a solid
chassis to earth ground wire.
The ice maker should be connected to its own
electrical circuit so it would be individually fused.
Voltage variation must remain within design
limitations, even under starting conditions.
Electrically the remote condenser fan motor is
connected to the ice maker at the contactor
terminals for the compressor and the fan motor
operates whenever the compressor operates.
Electrical connections are made at the junction
box at the back of the ice maker and at the
junction box on the remote condenser.
The remote condenser must be wired to the ice
maker in accordance with local and national
electrical codes with a minimum of 18 Awg.
wire with an ground bonding wire connected to
the ground screws provided in both the
condenser and machine field wiring boxes. All
outdoor wiring must be in rain proof conduit.
All external wiring must conform to national,
state, and local electrical codes. The use of a
licensed electrician is required to perform the
electrical installation.
NME954R & FME1204R
January 2000
Page 10
Terminal Strip For
Remote
Condenser
Ice Maker
Junction Box
Power
Supply
Ground The
Chassis
Rain Proof Conduit