COMPONENT DESCRIPTION: Control Box
Contactor: A definite purpose contactor
connecting the compressor and the fan motor to
the power supply.
Circuit Board: Controls the operation of the ice
machine using input from sensors and pressure
controls. Switches loads on and off thru relays.
Transformer: Supplies low voltage to the circuit
board.
Low Pressure Cut Out Switch: A manual reset
control that shuts off the ice machine when the low
side pressure drops below a preset point, 0-4 psig.
Potential Relay : The compressor start relay.
On/Off Switch: Manual control for the machine.
ON/OFF SWITCH
LOW
PRESSURE
CUT OUT
SWITCH
POTENTIAL
RELAY
TRANSFORMER
CONTACTOR
CIRCUIT
BOARD
"No Water " light,
glows when there is
not enough water in
the reservoir
"Bin Empty" light,
glows when ice level is
below electric eyes.
Control Box
NME950 & FME1200
January 1995
Page 11