///////////////////////////////////////////////////////////////////////WARNING//////////////////////////////////////////////////////////////////
These procedures require the machine to be connected to the power supply. The voltages of the
electronic circuit are very low, but HIGHER VOLTAGES ARE PRESENT IN THE UNIT. Do not
touch anything but the tester while the unit is being checked out. Make all connections to the
circuit board with the ELECTRICAL POWER OFF.
///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
INSTRUCTIONS FOR USING TESTER, model FC1 (Optional, order part no. A33942-001)
(These instructions assume that the unit will not run, and prior investigation of electric power,
controls, and mechanical parts indicates that the electronic circuit may be at fault.)
If the "Reset" indicator (located in the "reset" switch) is off and the "NO WATER" indicator is lit,
but inspection shows that the water level in the reservoir is above the top of the water level
sensor, OR the "BIN EMPTY" indicator is off while inspection shows that the ice level sensors are
properly aligned, clean and not obstructed, use the tester as follows:
Bin Control
Note: All testing is done with the
electrical power on, the master switch on, and
all reset switches “reset”.
1. Unplug “photo trans” and “LED” connectors
from the circuit board.
2. Plug “photo trans” and “LED” connectors
from the tester into the circuit board.
a. Move the “bin full” switch on the tester to
Full. The light on the tester should be ON.
If the light on the tester is not on, the circuit
board should be replaced.
b. If the light on the tester IS on, move the
“bin full” switch to Bin Empty. The light on the
tester should go OFF, and the Bin Empty light
on the circuit board should go ON.
If the Bin Empty light is ON, wait 10-20
seconds for the machine to start, if the
machine starts, replace the ice level sensors.
If the Bin Empty light does not come ON, the
circuit board should be replaced.
CIRCUIT BOARD TESTING
PHOTO
TRANS
LED
LIGHT GOES
ON
SWITCH TO
"FULL"
LIGHT GOES
ON
LIGHT
GOES
OFF
SWITCH TO
"BIN EMPTY"
FM1500
February, 1989
Page 30