FOR THE ELECTRICIAN
SEE NAMEPLATE for current requirements to
determine wire size to be used for electrical
hookup. When the cuber and the remote
condenser are connected, each must be grounded
to the other using the ground screws provided in
the respective junction boxes. The cuber then
requires a solid chassis to chassis earth ground
wire. See Wiring Diagram.
Be certain the cuber is connected to its own
electrical circuit and individually fused. Voltage
variation should not exceed ten percent of the
nameplate rating, even under starting conditions.
Low voltages can cause erratic operation and may
be responsible for serious damage to the
icemaker.
The remote condenser is designed to be powered
from the ice machine. There is a separate
electrical junction box at the back of the ice maker
for the remote condenser. Wire the remote
condenser to the ice maker in accordance with
local and national electric codes. All outdoor wiring
must be in rain proof conduit.
The condenser fan motor will run whenever the
compressor is running.
Electrical connections are made at the rear of
the icemaker, inside the junction box.
All external wiring should conform to the
national, state and local electrical code
requirements. Usually an electrical permit and
services of a licensed electrician will be
required.
ELECTRICAL CONNECTIONS
HAND
DISCONNECT
SWITCH
REMOTE CONNECTION
INTERCONNECTING
WIRES
CME500R
October 1994
Page 7