background image

April, 2016

Page 16

C0530E through C1030E

Remote Condenser Models - User Manual
Use and Operation

Once started, the ice machine will automatically make 

ice until the bin or dispenser is full of ice.

When ice level drops, the ice machine will resume 

making ice.

Caution: Do not place anything on top of the ice 

machine, including the ice scoop. Debris and moisture 

from objects on top of the machine can work their way 

into the cabinet and cause serious damage. Damage 

caused by foreign material is not covered by warranty.

There are four indicator lights at the front of the 

machine that provide information on the condition of 

the machine.

Indicator Lights:
•  Power
•  Status
•  Water
•  De-Scale & Sanitize

Indicator Lights & Their Meanings

Power 

Status 

Water 

De-Scale & Sanitize

Steady Green 

Normal 

Normal – bin full or 
making ice 

-

Blinking Green

 Self Test Failure

Switching on or off

 -

 -

Blinking Red

 - 

Diagnostic shutdown 
or, if making ice, 
temperature sensor 
failure

Lack of water

-

Yellow

 -

 -

 - 

Time to de-scale and 
sanitize

Blinking Yellow 

-

 -

 - 

In Cleaning mode

Light off 

No power 

Switched off 

Normal 

Normal

All Blinking

Unit remotely locked out – check with leasing company

If the Water light is on, the machine has sensed a 

lack of water. Check the water supply to the machine. 

The water may have been shut off or the water filter 

cartridges need to be changed.

If the De-Scale light is on, the machine has 

determined that it may need to be cleaned. Contact 

an authorized Scotsman service agent and have the 

machine cleaned, de-scaled and sanitized.

Note: A Component Indicator Light switches ON to 

indicate that the component is operating.

Note: There are two Curtain Switch lights, SW1 and 

SW2. These single plate models have 

one curtain 

switch light on all the time

 (either one), as a curtain 

switch light is ON when a curtain is either open or not 

present.

Содержание C0530 PRODIGY PLUS

Страница 1: ...Installation and User s Manual for Remote Condenser Modular Cuber Prodigy Plus E Series Models C0530 C0630 C0830 and C1030 ...

Страница 2: ...erson with the information needed to properly install and start up this ice system The Use and Operation section provides the user with the information needed to use the machine The Maintenance section contains the instructions and schedules for the sanitation and cleaning of the machine Contents Installation Product Specifications 2 Model Number Description 3 C0530 C0630 C0830 and C1030 Cabinet D...

Страница 3: ...m Maximum Air temperature 50o F 100o F Water temperature 40o F 100o F Water Pressure 20 psi 80 psi Environmental Limitations remote condenser Minimum Maximum Air temperature 20o F 120o F Power Supply Minimum Maximum 115 volt model 104 volts 126 volts 208 230 volt model 198 volts 253 volts Warranty Information The warranty statement for this product is provided separately from this manual Refer to ...

Страница 4: ...e the table below Standard bin applications Adapter information Model B530P B330P B530S B842S B948S C0530 C0630 C0830 C1030 Direct fit KBT28 KBT22 Hotel Dispenser Although an unlikely use for a remote cuber HD30 can be used without an adapter HD30 use with C0530R Ice and Beverage Dispensers Adapter Information Model ID150 ID200 or ID250 C0530 C0630 C0830 C1030 Does not fit KBT44 Other bins and app...

Страница 5: ...06 61 1 24 76 62 9 17 35 44 1 13 81 35 1 2 20 5 6 3 07 7 8 13 47 34 2 6 11 15 5 20 59 52 3 1 48 3 8 2 10 5 3 3 8 FPT WATER INLET 3 4 FPT DRAIN REMOTE CONDENSER LIQUID LINE 3 8 MALE CPLG REMOTE CONDENSER DISCHARGE LINE 1 2 MALE CPLG 88 DIA ELECTRICAL ACCESS 2 REMOTE COOLED BACK VIEW 24 00 REF 30 00 REF 2 00 5 1 2 00 5 1 19 05 48 4 3 25 8 3 10 25 26 7 00 17 8 ICE DROP OPENING ULTRASONIC BIN LEVEL SE...

Страница 6: ...as Small Series revision code omitted All the listed condensers include a headmaster valve Central Condenser Coils The ice machine may be connected to a central condenser coil The requirements are Coil not previously used with mineral oil system Virgin coil preferred Correct size internal volume and capacity BTUH Includes a headmaster valve for discharge pressure control Headmaster kit available f...

Страница 7: ... the machine Most water filters remove chlorine from the water supply to the machine which contributes to this situation Testing has shown that using a filter that does not remove chlorine such as the Scotsman Aqua Patrol will greatly improve this situation while the ice making process itself will remove the chlorine from the ice resulting in no taste or odor impact Additionally devices intended t...

Страница 8: ...tings Write the model and serial numbers here Model Serial Number Ice machine Bin Condenser Write the day of start up here _______________ Uncrate and Set Up Begin with the ice storage bin or dispenser If a bin remove the carton and using part of the carton as a cushion tip the bin on its back to remove the skid Attach the supplied legs or optional casters Return the bin to a normal upright positi...

Страница 9: ...n dd rd hd Calculated Line Length Configurations that do NOT meet these requirements must receive prior written authorization from Scotsman Do NOT Route a line set that rises then falls then rises Route a line set that falls then rises then falls Calculation Example 1 The condenser is to be located 5 feet below the ice machine and then 20 feet away horizontally 5 feet x 6 6 33 33 20 53 This locati...

Страница 10: ...age Meet all applicable building codes Roof Attachment Install and attach the remote condenser to the roof of the building using the methods and practices of construction that conform to the local building codes including having a roofing contractor secure the condenser to the roof Remote Condenser Electrical Connection Remote Condenser Refrigerant Connections Remote Condenser Ice Machine Refriger...

Страница 11: ... with swage tool if needed At Head 1 Remove the tubing access bracket to allow more room for brazing 1 Confirm connection ball valves are fully closed 2 Remove protective plugs from both connections 3 Remove caps from access valve connections 4 Remove cores from access valves 5 Connect refrigeration hoses to access valves 6 Connect dry nitrogen source to liquid line connection 7 Shorten tubing to ...

Страница 12: ...pply to water inlet fitting Note This NSF listed model has a 1 anti back flow air gap between the potable water inlet tube end and the highest possible reservoir water level no back flow device is required 2 Connect drain tubing to drain fitting 3 Route the drain tubing to building drain Follow local codes for drain air gap Use rigid drain tubes and route them separately do not Tee into the bin s ...

Страница 13: ...hine A separate knockout hole has been provided in the ice maker electrical junction box Electrical connections are made inside the junction box in the back panel of the ice machine 1 Remove the junction box cover and route the power cord through the access hole and properly attach the power supply wires to the leads in the junction box 2 Attach the remote condenser fan motor wires to the wires in...

Страница 14: ...oved 12 Is the water pressure adequate 13 Have the drain connections been checked for leaks 14 Has the bin interior been wiped clean or sanitized 15 Have any water filter cartridges been replaced 16 Have all required kits and adapters been properly installed Lower Light and Switch Panel This user accessible panel provides important operational information and duplicates the lights and switches on ...

Страница 15: ...evaporator and Off when returned to its normal position Note Moving the curtain during the Freeze cycle has no affect on control function but will cause water to flow into the cube chute 5 Observe the Ready for Harvest indicator light It may blink early in the freeze cycle that is normal The control will ignore that signal for the first 6 minutes of freeze 6 When the ice has frozen enough the Read...

Страница 16: ...factory set to automatically adjust the amount of water purged per cycle The setting can be changed to one of 5 manual settings or left on automatic Purge setting 1 Minimum 2 Moderate 3 Standard 4 Heavy 5 Maximum A Automatic Water Type RO water or equivalent TDS less than 35 Low TDS non RO water Setting for typical water High TDS water Very High TDS water greater than 256 Factory setting suitable ...

Страница 17: ...ice Blinking Green Self Test Failure Switching on or off Blinking Red Diagnostic shutdown or if making ice temperature sensor failure Lack of water Yellow Time to de scale and sanitize Blinking Yellow In Cleaning mode Light off No power Switched off Normal Normal All Blinking Unit remotely locked out check with leasing company If the Water light is on the machine has sensed a lack of water Check t...

Страница 18: ...in or dispenser is full Reasons for this include Seasonal changes in ice used Planning to sanitize the bin Faster turnover for fresher ice Certain dispenser applications where maximum ice level is not desired Use of adjustable ice level control There are several positions the ice level can be set to including Off knob and label indicators lined up where it fills the bin until the standard bin cont...

Страница 19: ...in to refill it Note Curtain must be in the closed position Move curtain to release any ice trapped after ice is harvested 5 Observe code display when it blinks the characters A d 1 immediately go to the next step 6 Pour 10 ounces C0530 or C0630 or 12 ounces C0830 or C1030 of Scotsman Clear 1 ice machine scale remover into the reservoir The unit will circulate the scale remover then drain and flus...

Страница 20: ... are completely dry 18 Push and release the Clean button The yellow Clean light will blink and the display will show C The machine will go through a harvest cycle drain the reservoir and begin to refill it 19 Observe code display when it blinks the characters Ad1 immediately go to the next step 20 Pour the sanitizing solution into the reservoir until it is full The unit will circulate the sanitize...

Страница 21: ... be blown out with compressed air from the inside or use a vacuum cleaner and soft brush Be careful not to damage the condenser s fins Use a fin comb to straighten any bent fins Exterior Panels Fingerprints dust and grease will require cleaning with a good quality stainless steel cleaner Water filters If the machine has been connected to water filters check the cartridges for the date they were re...

Страница 22: ...remote condenser while the ice machine still had power If yes the ice machine may need to be manually reset 4 Is the curtain open because some ice is stuck under it If so remove the ice and the machine should start in a few minutes Note Curtain can be removed replaced anytime the machine is in a standby mode or when it is in a freeze cycle However removal of the curtain during freeze will result i...

Страница 23: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 726 8762 17 3599 03 ...

Отзывы: