38) [Message Full Warning] 

 
When Tick box is checked, a “Message Full” warning will be shown 
on the display when the maximum number of messages has been 
reached. 
 

39) [Low bat special alert] 

 
When Tick box is checked, to indicate low battery condition the 
pager will vibrate pattern B for 3 seconds every 15 minutes until the 
battery is changed. The low battery icon will also be shown on the 
display continuously until battery is replaced. 
 

40) [Out of range special display] 

 
For use only with a Scope supervised transmitter system. When 
pager goes out of range, display will show “No Service” and vibrate 
continuously until reset by the user (pressing any button). A three 
second reminder vibrate alert will be sent every 15 minutes until the 
pager comes back into range. 
 

41) [Alarm Function] 

 
When Tick box is checked, alarm clock function is enabled. Note: 
time display must also be enabled for this feature to operate. 
 

42) [Auto On/Off Enable] 

 
When Tick box is checked, Auto On/Off function is enabled. See 
also item 25 above. 
 

43) [Canned Message] 

 
When Tick box is checked, up to four preset messages of up to 
twenty characters in length can be entered. These are displayed by 
sending a tone only A, B, C or D call.   
 

Содержание GEO 40A7

Страница 1: ...Scope Communications UK Ltd Ref 40A7PROGMANUAL Page 1 of 11 Issue 1 Programming Manual For GEO 40A7 Alphanumeric Pager ...

Страница 2: ...ent 2 Memory Size 10 000 character total 3 Display 5 8 dot matrix backlit LCD 4 Character 40 2 lines of 20 5 Messages Maximum 60 private 6 Message control Max 239 char per message 7 Public Private 24 folder 6 addresses 8 Standby screen Month Date Year Current Time 9 Error Message Blinking character 10 Number of Keys Fixed 4 keys ...

Страница 3: ... red indicator is lit 2 Copy the programming S W to your local hard disk Programming 1 Start the program and select the relevant features on the two page menu as described below 2 Remove the battery cover battery from the pager and insert the pager into the shoe Close the locking bar Click on Write to Pager on the top toolbar The screen will show progress and will confirm successful completion 3 T...

Страница 4: ... Call function see below is selectable for all 6 addresses on any tone type Tick box labelled Uch All cap codes are frame independent Capcodes must be within the following ranges 8 2007663 2007672 2045055 2045064 2097143 2 Message Folder Where addresses are set to Public for wide area paging service only up to 24 separate folders can be enabled Page 2 Feature On Off Menu 3 Num Char Set 0 9AU is th...

Страница 5: ...receive the same message within the set detecting time Variable between 1 15 minutes 8 Alert Time Alert period is adjustable between 1 255 seconds 9 Alert Mode ABCD Tone pager will respond and differentiate between four standard beep types A B C D Melody pager menu will offer a selection of 10 melodies which can be manually set by the user 10 Alert Type User select pager menu will offer the option...

Страница 6: ...t call mode is triggered Two Tone Vibrate as above but with additional vibrate pattern corresponding to the Vibrate Type set when set to ABCD Vibrate alert type is pattern A 13 Range Indicator Allows display of antenna icon to indicate that the pager is either In or Out of range applicable to wide area and supervised private paging only 14 Range Hold Time If the pager does not see sync from a tran...

Страница 7: ...r data transmission speed must be set to match the system transmitter if unsure of this check with your dealer stating the transmitter serial number 20 Data Polarity Data can be sent from the transmitter in Normal or Inverted mode Default is Normal 21 Channel Freq The operating frequency of the pager in MHz which must match the transmitter if unsure of this check with your dealer stating the trans...

Страница 8: ...the Low Battery alarm is triggered The default is 16 seconds which is normally used to prevent false alarms which might occur if the voltage momentarily dips to the preset level 27 Hello Message A message of up to 40 characters can be entered This will be briefly displayed each time the pager is switched on 28 Quiet Sound When the Tick box is checked the audible beep alert is reduced in volume for...

Страница 9: ... fixed or suffixed to the message using the prefix tick box 34 Time Stamp When Tick box is checked messages will be time stamped This can either be pre fixed or suffixed to the message using the prefix tick box Note that Time Display must be enabled 35 Hand Program When Tick box is checked allows user to hand program the frequency capcodes and baud rate settings 36 Auto Spacing When Tick box is ch...

Страница 10: ...isplay For use only with a Scope supervised transmitter system When pager goes out of range display will show No Service and vibrate continuously until reset by the user pressing any button A three second reminder vibrate alert will be sent every 15 minutes until the pager comes back into range 41 Alarm Function When Tick box is checked alarm clock function is enabled Note time display must also b...

Страница 11: ...he command codes as shown below In order for the code to work properly you must have the following set in the pager OTA Power OFF 0091 0 1 Identify a Cap Code Beep Type as Numeric A B C or D 2 Send N0100008A 0091 0 The pager will turn off OTA MSG DEL 0092 0 1 Send N0100008A 0092 0 All Memory will be cleared ...

Отзывы:

Похожие инструкции для GEO 40A7