Scope Communications UK Ltd
Ref: 40A7PROGMANUAL
Page 6 of
11
Issue 1
11) [Vibrate Type]
When set in vibrate mode, various vibrate patterns can be set.
Continuous: vibrate alert lasts for the duration of the Alert Time set.
1 Hz pulse: vibrate pulses once a second for the Alert Time set.
ABCD: vibrate pulses in sympathy with the ABCD call patterns.
Special: distinct Scope preset vibrate pattern to easily distinguish
between ABCD calls.
12) [Urgent Call Type]
Two Tone: two alternating tones give a distinct alert when the Urgent
call mode is triggered.
Two Tone + Vibrate: as above but with additional vibrate pattern
(corresponding to the Vibrate Type set*)
*when set to ABCD Vibrate, alert type is pattern A
13) [Range Indicator]
Allows display of antenna icon to indicate that the pager is either In
or Out of range (applicable to wide area and supervised private
paging only).
14) [Range Hold Time]
If the pager does not see sync from a transmission within the set
time, it will display the In/Out of range icon. Settable between 1 and
15 minutes.
15) [LCD Hold Time]
The time that the display remains active after receiving a call.
Adjustable between 1-255 seconds. “0” = always on.
16) [LCD Contrast]
Defines the preset display contrast. Settable range of 08-63. Default