A
B
+
CR 2354
3V
+
CR 2354
3V
fixing holes
LED Indicator
adjustment
lines
battery
DIP switches
cover tamper
switch
1 2 3 4
ON
OFF
25
mm
190
mm
10
mm
rear
tamper
sensors
5
mm
The JA-82M is designed to detect opening windows,
doors etc. It can be installed into most plastic or
wooden frames.
The JA-82M detector is suitable for indoor installations only.
Installation should only be undertaken by technicians holding
a certificate issued by an authorised distributor. The detector
must not be exposed to bending or other deformation, as it
may become damaged.
The detector reacts to the removal of the magnetic button.
The electronics should be installed onto the non-moving part
of windows or doors, and the magnet onto the moving part.
The magnetic button should be installed into the window /
door between the moving and non moving parts, where the
closing mechanism is located. Prior to installation ensure that
the detector fits the given window/door type. In the case of a
wooden frame with too narrow a profile it is usually possible
to mill out a groove for detector insertion.
magnetic
button
JA-82M - Wireless Magnetic Door/Window Detector
For use with the range of switching receivers.
e.g. RFSA-61B, RFSAI-61B, RFSA-62B, RFSA-61M & RFSA-66M
The Components
Installation - Overview
1. Find a suitable part of the window / door frame for the
detector’s location (within the frame rebate) so that the
magnet can be aligned with the A (or B) adjustment line when
the window/door is closed. After opening the window/door,
the magnet’s distance from the detector should increase
by at least 2 cm.
2. Avoid locating the detector directly onto a metal frame as
metal impairs the functioning of the magnetic sensor and
radio communication. Avoid installing the detector onto the
bottom part of the window/door frame due to possible water
condensation.
3. Screw the magnet onto the moving part of the door /
window. Use a non-metallic back-plate if the frame groove is
too wide.
4. Unscrew the battery cover and screw the detector to
the frame, so that the magnet is aligned with the A (or B)
adjustment line when the window / door is closed. Be careful
not to over tighten the screws as the detectors plastic body
could be damaged.
5. Plastic plates are supplied for use with uneven surfaces.
After the detector has been installed, at least one of the rear
tamper sensors must be permanently closed (pressed).
6. Test the device, to ensure the device does not obstruct
closing of the window or door.
7. Programming of the detector to switching receiver see
overleaf.
Installation
There are four DIP switches located under the battery cover:
No.
OFF
ON
1
Rear tamper sensors
OFF
Rear tamper sensors
ON
2
Permanent window/
door status signalling
Only window/door opening
will be signalled
3
No function
The reciever will
respond without a delay
4
No function
No function
DIP Switches
Default settings are shown in bold
www.click-smart.com