background image

Pairing The Detector:

Step 2 - Assign The Device

The device will now switch on / off without any delay. 
To programme an off delay proceed to the next step, to 
exit programming proceed to step 4.

Press & hold the ‘programming’ button on the receiver for 2 seconds 
(the status LED will flash with a 1 second interval).

Programming button

Status LED
Will flash once per 
second

Press and hold 2 
seconds

Step 1 - Activate The Receiver

To exit programming mode press the 
programme button for 1 second only.

Replace the battery cover.

Press and hold for 1 
second

Step 4 - Save And Exit

B. Press and hold programme button for 
8 seconds - this will delete ALL stored functions
Release programming button and then press for <1 second to exit

Select A or B To Delete Stored Function

Insert the batteries, replace the cover, after ten 
seconds close and open the door / window, the 
receiver LED will flash at an increased speed 
once to confirm detector assignment.

Step 3 - To Prepare For Function 5

Remove batteries - wait 30 seconds
Re-insert batteries to set time delay mode
Remove for another 30 seconds
Press button on receiver for < 5 seconds to start counter
When required time elapsed re-insert batteries

Switching Actuator Function 5 - ‘OFF DELAY’

Remove cover to reveal battery compartment

A. Press and hold programme button for 
5 seconds the LED will flash twice a second. 
Remove and re-install batteries - this will delete 
the single pairing.

Always replace both battery cells at the same time. 
We recommend using a high quality brand name battery (e.g. Panasonic). 

After the batteries have been replaced, detector function should be tested. 

Expired batteries should be disposed of according to local regulations. 

Battery Type: 

 

 

 

 

 

 

CR2354 Lithium

Voltage:  

 

 

 

 

 

 

3.0V DC

Typical battery life:  

 

 

 

 

 

Approx. 3 years (for 5 daily activations)

Communication band:    

 

 

 

 

868 MHz

Communication range:    

 

 

 

 

Approx. 200m (open area)

Operational environment according to EN 50131-1  

 

II.indoor general

Operational temperature range:    

 

 

 

-10 to +40 °C

Dimensions:  

 

 

 

 

 

 

85 x 60 x 55 mm

EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification: 

Grade 2

Complies with:   

 

 

 

 

 

ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1

Can be operated according to:    

 

 

 

VO-R/10/05.2006-22

Battery Replacement

Technical Specifications

Scolmore Park, Landsberg, Lichfield Road Industrial Estate, Tamworth, Staffordshire B79 7XB
Tel: +44 (0) 1827 63454                     Fax: +44 (0) 1827 63362     

         www.scolmore.com