SAFETY PRECAUTIONS

Keep CLEANER away from children!

Please store the ultrasonic cleaner where it is not reachable by children.
Danger to children! Danger of death through suffocation! Keep the packaging material
from children.
This appliance shall not be used by children. Keep the appliance and its cord out of reach of
children.

  To prevent life-threatening electrical shock, please observe the 

following:

 Danger of electrical shock!  Do not use while bathing. Never immerse the device or the power cord 
in water or other liquid.
•   Danger of electrical shock! Never touch the power plug with wet hands, especially inserting or 

removing the plug.

•   Danger of electrical shock! If the unit has fallen into water during operation, do not touch the 

unit. Remove the power plug from the socket first.

•  Danger of electrical shock! Do not spray water or liquid over the device. 
•  Never operate the device unattended.
•  Follow the manual to operate the device.
•  Do not use components unapproved by the manufacturer.
•  When removing the power cord from the socket, grab the power plug not the cord.
•   To protect the power cord from damage, do not cause it to get caught by things such as a  

cupboard door or a chair leg; do not drag across a hot surface.

•   If there is damage to the power plug, cord, housing, or other parts of the device, do not use the  

device.

•  Do not disassemble the device, except by professionals.
•   If the unit is damaged, non-operational or has fallen into water, take it to an authorized dealer for 

service.

•   Remove the power plug from the socket:

 

-

if malfunction occurs before cleaning the device

 

-

if the device is not going to be used for prolonged period after each use (recommended)

•   The installation of an earth leakage circuit breaker with a rated tripping current of no more than  

30 mA provides further protection against an electrical shock. The installation should only be 
carried out by a trained electrician.

 To prevent fire hazards, please observe the following:

•  Never block the vents on the device. Keep the vents free from lint, hair and other materials.
•   Do not place the device on a soft surface, such as a bed or a couch, where the vents could be 

blocked.

•  Observe the other warnings in the previous section.
•   If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a 

similarly qualified person in order to avoid a hazard.

SD-485 US EN R1_StatClean user manual.indd   4

2016-06-09   12:58 PM

Содержание StatClean

Страница 1: ...usage timer Independent control circuit for each ultrasonic transducer 40 higher cleaning efficiency not susceptible to interference more durable Multiple circuit protectors When overloaded or imprope...

Страница 2: ...ith capacitive sensing technology Durable reliable resistant to water and harsh chemicals Advanced power off memory that recalls last timer and temperature settings Electrical circuit features 1 Two s...

Страница 3: ...SSORIES 6 CONTROL PANEL AND OPERATIONS 7 OPERATION GUIDELINES 9 MEMORY OPERATIONS 11 COMMON CLEANING METHODS 12 PRODUCT EXPLODED VIEW 14 CARE AND MAINTENANCE 16 OPTIONAL ACCESSORIES 17 SPECIFICATIONS...

Страница 4: ...e do not cause it to get caught by things such as a cupboard door or a chair leg do not drag across a hot surface If there is damage to the power plug cord housing or other parts of the device do not...

Страница 5: ...using the appliance To reduce the risk of injury close supervision is necessary when an appliance is used near children Only use attachments recommended or sold by the manufacturer Do not use outdoor...

Страница 6: ...Indicator 5 Solution Usage Remaining Time 6 Solution Warning Light 7 Degas Status 8 Normal Cleaning Status 9 Heater Status 10 Working Status 11 Heater Key 12 Funtion Key 13 On Off Key 14 Decreasing Ke...

Страница 7: ...bubbles on the tank walls These will reduce the cleaning effect in the beginning phase of ultrasonic cleaning Turning on the degas function will dissipate the droplets and the air bubbles usually in...

Страница 8: ...d pressing the button each time reduces the timer buy 1 minute b When Temp is used pressing the button each time reduces the set temp down to the next level c When h min is used pressing the button ea...

Страница 9: ...evel The digital timer will count down to show the remaining cleaning time When it displays 00 00 the cleaning cycle stops To stop cleaning at any time press On Off button twice The unit is equipped w...

Страница 10: ...running for 50 minutes OPERATION GUIDELINES When cleaning is completed switch off the power open the lid and retrieve the basket and the items Alternatively raise and suspend the basket above water a...

Страница 11: ...g cycle is started It will not stay if the power is turned off f If the On Off key is touched twice during the cleaning cycle the cycle will stop and the timer setting will stop running It ll resume t...

Страница 12: ...s Basket can reduce the friction between the items and the tank 2 During cleaning dirt will come off like a cloud and the water will become murky over time When the cloud stops coming the cleaning is...

Страница 13: ...ned off automatically after 50 minutes D Special cleaning Silver copper or brass items with oxidation which has darkened the items will need special cleaning Cleaning Method 1 Put the items in the bas...

Страница 14: ...14 PRODUCT EXPLODED VIEW SD 485 US EN R1_StatClean user manual indd 14 2016 06 09 12 58 PM...

Страница 15: ...Spout ABS 23 Ball valve Standard part 24 Bracket ABS 25 Elbow ABS 26 Valve handle ABS 27 Bottom cover ABS 28 Power PCB 1 94V0 29 Power PCB 2 94V0 30 Cooling fan Standard part 31 Right handle ABS 32 R...

Страница 16: ...e heater from running hence to prevent damages to the unit and fire hazard The switch cuts off power for approximately 6 10 minutes then reconnect the power automatically Do not run the unit for exten...

Страница 17: ...r to drain water Place the beaker holder with beaker s across the top of the main cleaning tank as shown Add water to the main tank so the water level reaches the beaker s Add solution inside the beak...

Страница 18: ...P4862 Tank Capacity 6 0 L 1 6 gallon US Max 5 0 L 1 3 gallon US Min 3 35 L 0 9 gallon US Tank Size 32 3 x 20 5 x 9 9 cm 12 7 x 8 1 x 3 9 Longest Item Fits inside Tank 34 0 cm 13 4 Power Supply 260 W...

Отзывы: