6. 

Installation

Rangehood Size vs Cooktop Size

In addition to the size, the height of the rangehood above the cooktop is important to obtain  
the best performance.

INADEQUATE 

Rangehood smaller than  

cooking zone

ADEQUATE 

Rangehood same size as  

cooking zone

OPTIMAL 

Rangehood larger than  

cooking zone

Overhead cabinet Rangehood Installation position

It is important to consider the benchtop and overhead cabinetry depth before installing the rangehood.

The information below is to be used as a guide only, drawings are not to scale and do not account  
for all circumstances. 

The cooktop is centrally installed in the benchtop in the diagrams below.

GOOD

600mm

600mm

600mm

400mm

Side View 

Side View 

BETTER

450mm

BEST

500mm

When the overhead cabinetry is 
constructed and installed deeper 
than standard, ensure the rangehood 
is installed as close to the front 
as possible. This will increase the 
rangehood extraction results as there 
is a greater coverage of the cooktop 
surface area.

Side View 

Содержание UM1390-9BS

Страница 1: ...DE UM1390 9S UM1390 9BS UM1390 9BS Revision V5 01 04 22 Under our policy of continuous product development product specifications may change without notice Please refer to the online version of the ma...

Страница 2: ...aning the Exterior 9 Filters 10 Replacing the Lights 11 6 Installation 12 Rangehood Size vs Cooktop Size 12 Overhead cabinet Rangehood Installation position 12 Mounting Instructions 13 Recommended Ins...

Страница 3: ...website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environmen...

Страница 4: ...person s including children with reduced physical sensory or mental capabilities or lack of experience and or knowledge Unless the person has been given supervision or instruction concerning the use o...

Страница 5: ...a qualified technician and that the indicated instructions and local regulations in force are met using materials that are compliant with the applicable legislation 11 The company will not be responsi...

Страница 6: ...ons After use always ensure that all controls are in the OFF position When frying with a gas flame take particular care not to allow the oil or grease in the pan to catch fire Flamb Electrical Cord En...

Страница 7: ...be accessible for service and or maintenance once installed failure to do so will result in any charges involved with accessing the part removal of cabinetry etc being forwarded to the customer 860mm...

Страница 8: ...ght cooking High speed for heavy frying or heavy cooking Cleaning periods of metal filters C Signal Filter should be cleaned when C signal appears on the display on average this is every 4 to 5 weeks...

Страница 9: ...liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the direction of the st...

Страница 10: ...r Dishwasher Put the filter in the dishwasher and select a short program at low temperature NOTE The colour of the metal mesh filters may change after several washes This is normal and it is not neces...

Страница 11: ...he pins of the light bulb with the larger holes inside the light holder Once the pins are in place turn clockwise to secure the light bulb Step 1 Remove the filters from the rangehood Danger Always sw...

Страница 12: ...and overhead cabinetry depth before installing the rangehood The information below is to be used as a guide only drawings are not to scale and do not account for all circumstances The cooktop is centr...

Страница 13: ...eigen recommends a height of between 700 750mm Refer to page 18 for further information IMPORTANT If the user decides to install the rangehood at a distance of less than minimum height above the cooki...

Страница 14: ...ed to be tighten with slightly angled screws to pull the rangehood up tight to the cabinet These support screws insert from the inside of the cabinet A B Wall Cabinet TOP VIEW BOTTOM VIEW SIDE VIEW SI...

Страница 15: ...o a support frame See Mounting and Fixing Points for more information Step 1 Insert support frame into cabinet The support will only be needed in certain circumstances NOTE The support frame is not in...

Страница 16: ...ed ducting creates sharp corners that creates turbulence This reduces the size and efficiency of the ducting lowers extraction and may cause excessive noise 2 Sweeping curves and taut ducting reduces...

Страница 17: ...T crush or kink the ducting 9 Connect ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting 6 Installation System Overview Pictures are for illustrative purposes only not t...

Страница 18: ...rom cooktop to the rangehood Speed of food liquid heating Filter size larger canopy preferred Quality of pots or cookware you are using high quality recommended How to reduce the possibility of conden...

Страница 19: ...LED globes should be firmly in position Check LED globes Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or with the back draft fins Check the outlet make s...

Страница 20: ...e appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online Service R...

Страница 21: ...170 part of filter 5 17 90 30 360 390 17 350 20 40 170 part of filter 5 17 9 Specifications Technical Specifications Model UM1390 9S UM1390 9BS Feeding Voltage 220 240V 50Hz Lamp Power LED W 2 x 3W Su...

Страница 22: ..._n_ _LH Section_ Page 22 9 Specifications 897 390 245 195 165 165 165 165 260 90 30 897 850 25 235 290 30 897 390 245 195 165 165 165 165 260 90 30 897 850 25 235 290 30...

Страница 23: ...be found with the Isodrive Motor or online at schweigen com au Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all p...

Страница 24: ...rive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emers...

Отзывы: