background image

Page 17

6. SteelFlex

 Safety Duct

SteelFlex

 Safety Ducting

SteelFlex

 safety ducting must be fully extended and cut to the required length upon installation. Maximum 

fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting 
results in a smaller air passage and lower airflows. Incorrect installation may reduce airflow or increase noise 
levels. Call outs relating to incorrect installation will result in a service fee directed to the customer. Schweigen 
will take no responsibility for problems caused by faulty installation. 

A list of preferred Schweigen 

installers can be obtained from the Schweigen website www.schweigen.com.au.

900 motor

Please keep the SteelFlex

 ducting 

taut, 4 metres in length with two  
gentle bends.

NOTE:

 In shallow roof spaces extend 

SteelFlex

 ducting horizontally

Содержание Isodrive 900

Страница 1: ...INSTALLATION GUIDE Isodrive 900 www schweigen com au Revision V2 25 11 21...

Страница 2: ...unit as well as important safety notes This will ensure your personal safety and the lasting value of your Isodrive system Please always retain your proof of purchase to aid in any warranty queries Th...

Страница 3: ..._________________________ 7 4 Installation Roof Installation ________________________________________________________________________________ 9 Wall Installation ______________________________________...

Страница 4: ...s indicated on the rating label Before Installation We recommend this appliance to be installed or repaired by a qualified Schweigen Home Appliances technician Please see our website www schweigen com...

Страница 5: ...etc General Notes on Installation and Use This fan unit is designed to be installed using 150mm ISD PVC pipe as the initial connection duct to the fan module and is supplied with a 150mm ISD PVC pipe...

Страница 6: ...x is antimicrobial treated thermally insulated and acoustically dampened It is fireproof pest and crush proof with a treated surface that prevents the build up of grease and bacteria Schweigen s uniqu...

Страница 7: ...Approx 4 metres 200mm 210mm OD1 diameter 4 Bell mouth adapter ring 200mm duct to 150mm riser 5 2 x Steel ring clamps 6 6 x 20mm self drilling button head screws Not included in the box Roof seal kit D...

Страница 8: ...coming from the canopy rangehood Refer to figure 4 Do not insert plug into socket outlet or switch on until installation has been completed Fit fan module to pipe and fix in position using side locki...

Страница 9: ...o prevent rain water entering the unit Pipe protrusion above dektite Fix fan module using side locking screw Connect to rangehood Connect to power supply NOTE Prevent any cord bunching by pulling cord...

Страница 10: ...eard through the system and inhibit the system to run silently Figure 2 Wall Installation Wall Wall Optional Fitment Pipe Optional Mounting Flange P40113MF 150mm PVC Stormwater Pipe From outside face...

Страница 11: ...Locking holes at 10 and 4 o clock Cord slots at bottom 6 o clock position NOTE Ensure that power cord is fed through exit slot and is not allowed to double back restricting fan inlet NOTE Prevent any...

Страница 12: ...remain 200mm SteelFlex Ducting Seal top edge of flange 50 Protrusion of pipe above mounting flange Bond flange to pipe using silicone urethane or type N PVC solvent cement Optional mounting flange P4...

Страница 13: ...r plate with notch at bottom P1108 Minimum pipe protrusion from wall surface Wall cover plate optional part Slot in pipe at bottom 6 O Clock Power cord Ensure that power cable passes through the cover...

Страница 14: ...les Alignment can be checked visually by folding in shutter flaps 2 Fully tighten both screws and re check fitment into holes 3 Fit assembly to duct pipe as per installation instructions supplied Atta...

Страница 15: ...Try to keep length of SteelFlex ducting as even as possible other wise motors will draw air off each other Ensure SteelFlex ducting is fully extended and as short as possible Use smooth flowing curve...

Страница 16: ...Page 16 5 Measurements Measurements for Isodrive 900 Not to Scale 157mm 53mm 278mm 198mm 440mm 160mm 242mm 131mm Dektite Shutter assembly optional is not shown in the diagram...

Страница 17: ...flows Incorrect installation may reduce airflow or increase noise levels Call outs relating to incorrect installation will result in a service fee directed to the customer Schweigen will take no respo...

Страница 18: ...l mouth adapter ring 200mm duct to 150mm riser 4 150mm PVC riser pipe 5 20mm self drilling button head screws 1 2 3 4 5 NOTE Do not use duct tape to fasten the duct the screws and hose clamp are adequ...

Страница 19: ...rely 90 degree curve made of PVC or galvanise can be used as a substitute for the bend refer to figure 12 Figure 12 Figure 13 Important Note Please do not crush or kink SteelFlex ducting as it will re...

Страница 20: ...Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual Support of the ducting with the use of hangers may be required see op...

Страница 21: ...Page 21 7 Parts List Parts List for Isodrive 900 1 2 3 4 5 6 7 8 9 10 11 12...

Страница 22: ...0 Terminal Block Cover 1 2 P40121 Wire Insulator Cap 1 3 P1061 O Ring 4 ID 1 4 P1059 Capacitor 2 F 1 5 P807 Terminal Block 1 6 P40102 Fan Plate Motor Mount 1 8 P40122 900 Inlet Shroud Mount 1 9 P1069...

Страница 23: ...doing your roof restoration or cleaning please completely cover the outside motor system and avoid all chemical contact IMPORTANT Any damages caused by the use of chemical products are not covered by...

Страница 24: ...er Under our policy of continuous product development product specifications may change without notice Prospective purchasers should therefore check with the retailer to ensure this publication correc...

Страница 25: ...Page 25 Notes...

Страница 26: ...Page 26 Notes...

Страница 27: ...Page 27 Notes...

Страница 28: ...rive Dingley Village Victoria 3172 Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emers...

Отзывы: