Safety 

• 

For all installations of electrically heated 
products a residual current circuit breaker 300 
mA for fire protection should be used. 

• 

Keep the areas around the air intake and 
exhaust grilles free from possible obstructions! 

• 

The unit must not be fully or partially covered 
as overheating can result in a fire risk! 

• 

Lifting equipment must be used to lift the unit. 

• 

This appliance can be used by children 
aged from 8 years and above and 
persons with reduced physical, sensory or 
mental capabilities or lack of experience 
and knowledge if they have been given 
supervision or instruction concerning use of 
the appliance in a safe way and understand 
the hazards involved. Children shall not 
play with the appliance. Cleaning and user 
maintenance shall not be made by children 
without supervision.  

• 

Children of less than 3 years should be kept 
away unless continuously supervised. 

• 

Children aged from 3 years and less than 8 
years shall only switch on/off the appliance 
provided that it has been placed or installed 
in its intended normal operating position and 
they have been given supervision or instruction 
concerning use of the appliance in a safe way 
and understand the hazards involved. 

• 

Children aged from 3 years and less than 8 
years shall not plug in, regulate and clean the 
appliance or perform user maintenance.

CAUTION — Some parts of this product can 
become very hot and cause burns. Particular 
attention has to be given where children and 
vulnerable people are present.

Residual current circuit breaker [TE]

When the installation is protected by means of a 

residual current circuit breaker, which trips when 

the appliance is connected, this may be due 

to moisture in the heating element. When an 

appliance containing a heater element has not 

been used for a long period or stored in a damp 

environment, moisture can enter the element. 

This should not be seen as a fault, but is simply 

rectified by connecting the appliance to the 

main supply via a socket without a safety cut-out 

so that the moisture can be eliminated from the 

element. The drying time can vary from a few 

hours to a few days. As a preventive measure, the 

unit should occasionally be run for a short time 

when it is not being used for extended periods of 

time.

Packaging

Packaging materials are chosen with 

consideration to the environment and are 

therefore recyclable.

Handling of product at end of
working life

This product may contain substances necessary 

for the functionality of the product but potentially 

dangerous for the environment. The product 

should not be disposed of mixed with general 

household waste but delivered to a designated 

collection point for environmental recycling. 

Please contact the local authority for further 

details of your nearest designated collection 

point. 

For units with a water coil, also check the 
following:

• 

That the water coil is air free.

• 

That there is sufficient water flow and pressure.

• 

That incoming water is heated adequately.

 

If the fault cannot be rectified, please contact a 

qualified service technician.

Содержание SchwankAir 4000-Recessed Series

Страница 1: ...are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program The AMCA Certified R...

Страница 2: ...7 0 600V3 29 287 Model Output 4 MBH Airflow 1 CFM Sound power 2 dB A Sound Pressure dB A Motor power W Voltage motor V Amperage motor A Water volume US gal Weight lb AC VW36 23 R 51 1350 76 58 503 20...

Страница 3: ...r temp F Water flow GPM Pressure drop kPa Output 2 MBH Outlet air temp F Water flow GPM Pressure drop kPa AC VW36 23 R max 1501 50 2 88 1 1 2 6 95 9 122 5 4 39 6 AC VW60 23 R max 1942 64 5 95 1 4 1 6...

Страница 4: ...mainly of pictures For translation of the English texts used see the respective language pages EN Les pages de pr sentation contiennent principalement des images Pour la traduction des textes en angla...

Страница 5: ...0 23 R C 82 68 AC VA72 23 R 82 68 AC VE72 20 48 60 R 82 68 AC VW72 23 R D 103 16 AC VA96 23 R 103 16 AC VE96 48 60 R 103 16 AC VW96 23 R E 40 8 AC VA36 23 R 40 8 AC VE36 20 48 60 R 40 8 AC VW36 23 R F...

Страница 6: ...essed Models All 96 Recessed Models A G H J L L J I K M C D D E F B Ref inch Model A 35 36 36 Models B 34 04 36 Models C 0 80 36 Models D 1 16 36 Models E 2 84 36 Models F 2 24 36 Models G 8 72 36 Mod...

Страница 7: ...schwankgroup com schwankair Fig 1b Mounting on threaded bars outside the unit Fig 1a Mounting brackets on delivery For 72 96 Models Mounting on threaded bars outside the unit...

Страница 8: ...0 72 Models T 2 24 72 Models U 11 64 72 Models V 29 68 72 Models W 15 88 96 Models X 28 92 96 Models Y 13 60 96 Models Z 17 20 96 Models AA 2 24 96 Models AB 11 68 96 Models AC 33 12 96 Models AD 13 5...

Страница 9: ...schwankgroup com schwankair Mounting on threaded bars outside the unit Fig 2 Mounting on threaded bars inside the unit 3 3 ft 4 x M8 4 9 ft 4 x M8 6 6 ft 6 x M8 8 2 ft 6 8 x M8...

Страница 10: ...schwankgroup com schwankair Fig 3 Snap fixings 90 Service hatch Fig 4 Controller inside the unit Fig 5 Hoses are mounted via cable glands at knockouts to protect the hose and prevent air leakage 1 2...

Страница 11: ...ers JC 0755 10 15 20 25 Intake Nozzle Extension Kit Ceiling Bracket Model Air Curtain Models Quantity included JC 0706 15 36 60 Models 4 pcs JC 0706 20 72 Models 6 pcs JC 0706 30 96 Models 8 pcs Vibra...

Страница 12: ...s JC 0742 XX Temperature Sensor JC 0745 XX Return Water Temp Sensor JC 0732 RJ12 Cable next to JC 0732 XX Different Lengths Available JC 0751 XX Water Heated Plumbing Kit JC 0751 XX 3 4 Plumbing Kit I...

Страница 13: ...Room C2 C1 Actuator 230VSupply 230V PE L N Heating L N L Trafo Motor protection 0 10V GND PWM L N Motor Internal sensor M M M M All Ambient Water Heated Models except 36 208V1 PE L1 L2 Wiring Diagram...

Страница 14: ...230VSupply 230V PE L N Heating L N L Trafo K2 K1 AC VE36 20 R AC VE60 20 R TS1 TS2 Motor protection 0 10V GND PWM L N Motor Internal sensor M M M M L1 L2 L3 L1 K2 L2 K2 L3 K2 L1 K1 L2 K1 L3 K1 208V3...

Страница 15: ...1 K 2 K 1 2 X 208V3 TS 2 TS 1 Moto r p rotec tio n 0 10 V GND P WM L N Moto r Inte rna l se n so r M M M M 208V3 L1L2 L3 72 96 Electric Heated 72 6 Motors 96 7 Motors L1 K 2 L2 K 2 L3 K 2 L1 K 1 L2 K...

Страница 16: ...30VS upply230V PE L N He ating L N L Trafo K 2 K 1 AC VE36 60 R AC VE60 60 R TS1 TS2 Motor protec tio n L N Motor Internal sensor M M M M 600 480V 230V Transformer 2 x 10A FUSE L1 L2 L3 2 1 3 600V3 48...

Страница 17: ...Trafo K2 K1 K2 K1 72 96 Electric Heated 2 X 600V3 480V3 TS2 TS1 TS3 TS4 Motor p rotection 0 10V GND PWM L N Motor Internal sensor M M M M 600V3 480V3 600 480V 230V Transformer FUSE 2 x 10A L1L2 L3 72...

Страница 18: ...Lock Parts Recessed JC 0543 XX AC VA36 23 R AC VA60 23 R AC VA72 23 R AC VA96 23 R 80 4000 Air Curtain Washer Recessed JC 0645 XX AC VA36 23 R AC VA60 23 R AC VA72 23 R AC VA96 23 R 75 4000 Air Curta...

Страница 19: ...Front Cover 60 Recessed JC 0649 15 AC VA60 23 R 4000 Air Curtain Front Cover 72 Recessed JC 0649 20 AC VA72 23 R 4000 Air Curtain Front Cover 96 Recessed JC 0649 25 AC VA96 23 R 25 4000 Air Curtain P...

Страница 20: ...group com schwankair Item Description Part Model 85 4000 Air Curtain Lock Parts Recessed JC 0543 XX AC VE36 20 R AC VE36 48 R AC VE36 60 R AC VE60 20 R AC VE60 48 R AC VE60 60 R AC VE72 20 R AC VE72 4...

Страница 21: ...AC VE72 60 R 4000 Air Curtain Inspection Casing 96 Recessed JC 0647 25 AC VE96 48 R AC VE96 60 R 45 4000 Air Curtain Contactor for Electric Heated Models JC 0615 XX AC VE36 20 R AC VE36 48 R AC VE36...

Страница 22: ...R AC VE60 20 R AC VE60 48 R AC VE60 60 R AC VE72 20 R AC VE72 48 R AC VE72 60 R AC VE96 48 R AC VE96 60 R 35 Internal Temp Sensor for Smart Controller JC 0663 XX AC VE36 20 R AC VE36 48 R AC VE36 60...

Страница 23: ...60 60 R 4000 Air Curtain Discharge Nozzle 60 JC 0606 20 AC VE72 20 R AC VE72 48 R AC VE72 60 R 4001 Air Curtain Discharge Nozzle 96 JC 0606 25 AC VE96 48 R AC VE96 60 R 10 4000 Air Curtain Nozzle Hold...

Страница 24: ...60 R 60 4000 Air Curtain Front Cover 36 Recessed JC 0649 10 AC VE36 20 R AC VE36 48 R AC VE36 60 R 4000 Air Curtain Front Cover 60 Recessed JC 0649 15 AC VE60 20 R AC VE60 48 R AC VE60 60 R 4000 Air C...

Страница 25: ...ecessed JC 0543 XX AC VW36 23 R AC VW60 23 R AC VW72 23 R AC VW96 23 R 80 4000 Air Curtain Washer Recessed JC 0645 XX AC VW36 23 R AC VW60 23 R AC VW72 23 R AC VW96 23 R 75 4000 Air Curtain Lock Pin R...

Страница 26: ...000 Air Curtain PCB JC 0604 XX AC VW36 23 R AC VW60 23 R AC VW72 23 R AC VW96 23 R 20 4000 Air Curtain EC Motor JC 0605 XX AC VW36 23 R AC VW60 23 R AC VW72 23 R AC VW96 23 R 15 4000 Air Curtain Disch...

Страница 27: ...t d installer l unit ou d en effectuer l entretien L installation ou l entretien de l unit doivent tre effectu s par un technicien qualifi seulement L unit ne doit pas tre install e et utilis e l ext...

Страница 28: ...ial across the doorway and any wind load NOTE Negative pressure in the building considerably reduces the efficiency of the air curtain The ventilation should therefore be balanced Electrical installat...

Страница 29: ...ection and speed of the airflow should be adjusted considering the load on the opening Pressure forces affect the airstream and force it inwards towards the premises when the premises are heated and t...

Страница 30: ...ned to within the motor s operating limits Temperature control Temperature control of the controller maintains the exhaust temperature If the temperature should exceed the preset value anyway the over...

Страница 31: ...ticular attention has to be given where children and vulnerable people are present Residual current circuit breaker TE When the installation is protected by means of a residual current circuit breaker...

Страница 32: ...3 Ajuster la hauteur via l crou sup rieur afin que le cadre soit au niveau du plafond Fixer en serrant l crou inf rieur Montage avec tiges filet es l int rieur de l appareil 1 Les utiliser avec des ti...

Страница 33: ...ue doit comporter la mention Les rideaux d air peuvent tre aliment s depuis plusieurs connexions Voir les sch mas de raccordement D marrage TE Lorsque l unit sert pour la premi re fois ou suite une lo...

Страница 34: ...es se bloquent correctement Surchauffe Le mod le chauffage lectrique est dot d un dispositif anti surchauffe Si ce dispositif se d clenche il convient de le r initialiser de la mani re suivante 1 D br...

Страница 35: ...eau suffisant Eau entrante suffisamment chaude Si le probl me persiste faire appel un technicien d entretien qualifi Purge de la batterie eau chaude TW La purge est situ e sous la batterie du c t du...

Страница 36: ...autoris s introduire la fiche r gler et nettoyer l appareil ou en effectuer la maintenance ATTENTION Certaines parties de l appareil peuvent devenir tr s chaudes et provoquer des br lures Il est n ce...

Страница 37: ...al for the controller Caract ristiques techniques Etages de puissance Puissance D bit d air Puissance acoustique FLA int nsit totale Puissance absorb e Tension moteur Intensit moteur Tension Intensit...

Страница 38: ...harge Caract ristiques techniques Nozzle deep x width Max Velocity at nozzle Outlet Velocity Outlet Velocity Uniformity Profondeur et largeur de la buse Vitesse maximale la buse Vitesse de sortie moye...

Страница 39: ...manual or if the serial number has been altered defaced or removed This warranty shall not apply if the electrical input to the product varies by more than 10 of the rat ed input on the rating plate...

Страница 40: ...kgroup com schwankair 1 877 686 3779 toll free 1 706 554 6191 csr schwankgroup com schwankgroup com schwankair USA 2 Schwank Way Waynesboro GA 30830 Canada 5285 Bradco Blvd Mississauga ON L4W 2A6 Schw...

Отзывы: