42
GP-MSET-EX-6A
SET(U) / ITT(U) Manual
RD: MAY 2009
RL: 06A- BA
Tube Kit Shipping
Weight (lbs)
120
170
210
165
165
120
165
Nominal Length (ft)
20'
30'
40'
30'
30'
20'
30'
MODEL
TM-1420-
SX
TM-1430-
SX
TM-1040-
SX
TM-F030-
SX
TM-1030-
SX
TM-0020-
SX
TM-0030-
SX
20'
1
30'
1
30'
1
40'
1
30'
1
40'
1
40'
1
50'
1+
1
1
50'
1+
1
60'
1+
1
50'
1+
1
60'
1+
1
TUBE KITS (Not emissive coated)
Stand-Alone tube kits require no additional tube kits.
Primary tube kits require at least one additional Secondary tube kit.
Secondary tube kit require a Primary tube kit.
'SET / ITT' TUBE KIT PART # & QUANTITY REQUIRED
Stand-Alone Kits
Primary Kits
Secondary Kits
80/60
110/75
130/90
155/110
175/125
200/140
26A. BURNER & TUBE KIT ASSEMBLY CHART MODELS S100 / ITB
MODELS SET & ITT are approved for indoor commercial / industrial non-residential applica-
tions. For outdoor, wet and harsh environment applications refer to models SPW-JZ / IWP
(powder coated burner box) and/or STW-JZ / IW (stainless steel burner box).
BEFORE INSTALLING: ENSURE you have the CORRECT TUBE KIT(s) for the
BURNER INPUT
USA
-
Stainless Steel Flexible Gas Connector
130,000 or less:
JL-0771-XX - 1/2”x24”
155,000 or more:
JL-0771-YY - 3/4”x36”
FLEXIBLE GAS CONNECTOR (Included in Burner Kit) - MUST INSTALL - see Section 13
CANADA
-
Type 1 Hose Gas Connector
130,000 or less:
JL-0771-RC - 1/2”x36”
155,000 or more:
JL-0771-RB - 3/4”x36”