background image

4BN/L6-24,4SN/L5 -24  Manual 

IM100310 

    RD: MAR, 2010  

RL: 1A - BA 

29 

 

 

FOR GAS-FIRED INFRA-RED PATIO HEATERS :  4SN/L-5-CB-24, 4BN/L-6-CB-24 SERIES 

Some Authorities do not allow certain warranty exclusions or limitations on how long a warranty lasts or the exclusions or 
limitations of incidental or consequential damages.  In such cases, the above limitations or exclusions may not apply to 
you and are not  intended to do so where prohibited by law.  This warranty gives you specific legal rights.  You may also 
have other rights which vary by each jurisdiction. 

                                                         

5285 BRADCO BLVD.    MISSISSAUGA, ON,    L4W 2A6 

 

 

 

 

 

2 SCHWANK WAY, WAYNESBORO,  GEORGIA.  30830-8336 

 

         SCHWANK INC.   

Ph: 905-712-4766 

 Fax: 905-712-8336 

         INFRASAVE INC.  

Ph: 1-866– INFRASV (463 7278)    Fax: 1-866-724 –9265 

LIMITED WARRANTY CERTIFICATE 

BURNER AND MANTLE - THREE YEAR WARRANTY 

The Manufacturer warrants the burner and mantle for a period of  three years

(3 years)

 

COMPONENT PARTS - ONE YEAR WARRANTY

 

Subject to the conditions and limitations stated herein, during the term of this limited warranty, we will repair or replace (at 
our option) any component part of the heater which the Manufacturer’s examination determines to be defective in work-
manship or material for a period of one year (1 year) from the date of installation, unless otherwise specified below. This 
warranty applies to the heater’s original owner, and subsequent transferees and only if the unit is installed and operated 
in accordance with the printed instructions accompanying the unit and in compliance with all applicable installation, build-
ing codes and good trade practices. 

WARRANTY PROCEDURE

 

To establish the installation date for any purpose under this Limited Warranty, you must retain the original records that 
can establish the installation date of your unit. If you do not provide such documents, the start date of the term of this Lim-
ited Warranty will be based upon  the date of unit manufacture, plus thirty (30) days. Failure to maintain the equipment 
through regular annual service maintenance by a qualified service technician shall void the warranty. 

LIMITATIONS AND EXCLUSIONS 

This document contains all warranties made by the Manufacturer and may not be varied, altered or extended by any per-
son.  There are no promises, or agreements extending from the Manufacture other than the statements contained herein.  
THIS WARRANTY IS IN LIEU OF ALL WARRANTIES EXPRESSED OR IMPLIED, TO THE EXTENT AUTHORIZED BY 
THE LAWS OF THE  JURISDICTION, INCLUDING SPECIFICALLY THE WARRANTIES OR MERCHANTIBILITY OF 
FITNESS FOR A PARTICULAR PURPOSE. 
It is understood and agreed that the Manufacturer’s obligation hereunder is limited to repairing or replacing parts deter-
mined to be defective as stated above. In no event shall the Manufacturer be responsible for any alleged personal injuries 
or other special, incidental or consequential damages. As to property damages, contract, tort or other claim the Manufac-
turer’s responsibility shall not exceed the purchase priced paid for the product. 
All replacement parts will be warranted  for the unused portion of the warranty coverage period remaining on the applica-
ble unit. 

WHAT IS NOT COVERED 

This warranty does not cover heating products improperly installed, misused, exposed to or damaged by negligence, acci-
dent, corrosive or contaminating atmosphere, water, excessive thermal shock, impact, abrasion, alteration or operation 
contrary to the owner’s manual or if the serial number has been altered, defaced or removed.  This warranty shall not ap-
ply if the input to the heating product exceeds by more than 2% of the rated input on the rating plate.  The Manufacturer 
shall not be responsible for any expenses, including service, labor, diagnosis, analysis, material or transportation charges 
incurred during removal or reinstallation of this product, or any of its components or parts.  All labor or service charges 
shall be paid by the owner.  The Manufacturer shall not be liable for any default or delay in performance by its warranty 
caused by any contingency beyond its control, including war, government restrictions, or restraints, strikes, fire, flood, acts 
of God, or short or reduced supply of raw materials or products. 

The Manufacturer warrants that this product is free from defects in material or workmanship under normal use and service 
subject to the terms of this document. 

GP-M424-CX-01A 

4BN/L6-24,4SN/L5 -24  Series  

WARRANTY  

APRIL, 2005 

RL: 1A 

TM 

Содержание 4BL6-CB-24

Страница 1: ...instructions thoroughly before installation operation or service to this appliance DANGER IF YOU SMELL GAS 1 Shut off gas to the appliance 2 Extinguish any open flame 3 If odor continues keep away fr...

Страница 2: ...reproduced in any form without prior written consent from the manufacturer Unauthorized use or distribution of this publication is strictly prohibited Schwank Group InfraSave 5285 Bradco Boulevard Mi...

Страница 3: ...TESTING 12 9 SAFE LOCATION OF HEATER 13 9 1 CLEARANCE TO COMBUSTIBLES 13 10 ELECTRICAL REQUIREMENTS 14 TOPIC PAGE NUMBER 11 LIGHTING OPERATION AND SHUTDOWN INSTRUCTIONS 15 12 MAINTENANCE 16 13 SEQUEN...

Страница 4: ...lammable or explosive objects liquids or va pors close to the heater may cause fire or explosion and result in property dam age injury or death The clearance to combustible material represents the min...

Страница 5: ...NOT BE HUNG FROM OR PLACED ON OR NEAR THE HEATER INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON THE HEATER SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A QUALI FIED SE...

Страница 6: ...her flammable liquids or va pors are stored Maintain adequate clearance around air openings into the combustion chamber This appliance is a gas fired infrared fixed post patio heater for outdoor use o...

Страница 7: ...s type and properly sized for each particular installation For your safety a complete gas tightness check of all connections and hoses must be performed at the installation site prior to use PRESSURE...

Страница 8: ...supply line 1 Install the proper gas type orifice see heater exploded view page 29 2 Convert Gas valve Conversion from NAT to LP or vice versa is accomplished by in verting the position of the conver...

Страница 9: ...type all other components are common for all models Note A gas pressure regulator s is required not supplied to regulate gas supply pressure The combination gas control valve in the heater has an inte...

Страница 10: ...nder the heater base typical Gas connection is concealed and protected under heater base With hose out through the access port in the post Gas connection is exposed sidewall above deck con nection Ens...

Страница 11: ...nections under the heater Ensure mounting hardware is of sufficient strength and integrity to support the heater in windy and other conditions that may be encountered Stainless steel hardware that doe...

Страница 12: ...or replace components at the leaking connection and repeat leak test proce dure The heater cannot be put into service until ALL gas leaks have ceased no matter how small Connect the natural gas supply...

Страница 13: ...ere gas vapours are present or inflammable liquids are stored or used In case of high winds completely shut off the heater and gas valve Remove reflector dome to secure storage if necessary 9 1 CLEARA...

Страница 14: ...e PROPER WIRING POLARITY MUST BE MAINTAINED particularly when grouping the heaters in a zone Total wiring distances of up to 200 must use minimum 16 gauge electrical wire and wiring dis tances of over...

Страница 15: ...d a second T F I If a flame is not established during this attempt an other inter purge and T F I will be performed If a flame is not established during the third final attempt the unit will enter the...

Страница 16: ...nually before the heater is put into service the heater should be inspected by a qualified gas service technician for spider webs insects and debris around burner and orifice A plugged in jector or or...

Страница 17: ...it will reset to try to ignite the gas again as in NORMAL OPERATION 6 If there is a loss of flame during the run mode the unit will energize the spark within 0 8 sec onds and perform a T F I without t...

Страница 18: ...4BN L6 24 4SN L5 24 Manual IM100310 RD MAR 2010 RL 1A BA 18 14 WIRING DIAGRAM 14 1 WIRING DIAGRAM WITH REMOTE CONTROL RECEIVER...

Страница 19: ...el and the heater s Total load of the heaters being con trolled must be considered in determining the contact rating of the thermostat If the installation provides an individual transformer for each h...

Страница 20: ...4BN L6 24 4SN L5 24 Manual IM100310 RD MAR 2010 RL 1A BA 20 16 OPTIONAL PATIO HEATER CONTROL PANEL WIRING 24 Vac...

Страница 21: ...ructions FEATURES House Code setting allows unique system address avoids interference with neighbor ing systems Works with Hand Set Transmitter YCT 107 Factory installed in heater CONNECTION Wiring Di...

Страница 22: ...ATE EVERY OTHER OR ODD SETTING POSITIONS A C E 1 3 5 THE EVEN POSITIONS B D F 2 4 6 ARE REPRESENTED BY A DOT Setting the House Code Adjust with slot screw driver Set the same house code on the transmi...

Страница 23: ...eceiver so that the Transmit ter Hand Set can control up to individual 16 heaters NOTE Within any zone of a patio best comfort is provided by the operation of two or more opposing heaters All receiver...

Страница 24: ...des 16 Positions For each area you wish to control with a separate transmitter select a unique code from A to P This avoids interference with neighboring con trol systems Set the same House Code on al...

Страница 25: ...will be controlled by Group 2 Buttons 1 and 2 Kits Part Numbers for Remote Control systems NOTE Items are ordered separately JP 1234 RK REMOTE CONTROL RECEIVER Typically Factory Installed order as opt...

Страница 26: ...patio site have a spare or back up Hand Set Transmitter that can be put into service if a first Hand set malfunctions or is mis placed Set up any spare or back up hand set s to the same House Code as...

Страница 27: ...park Check if spark Igniter is shorting out from the porcelain to ground Check Igniter gap setting is approx 3 16 Burner will not stay lit Sensor cracked bent or out of position Spark does not stop wh...

Страница 28: ...4BN L6 24 4SN L5 24 Manual IM100310 RD MAR 2010 RL 1A BA 28 19 REPLACEMENT PARTS EXPLODED VIEW...

Страница 29: ...document contains all warranties made by the Manufacturer and may not be varied altered or extended by any per son There are no promises or agreements extending from the Manufacture other than the sta...

Отзывы: