Schwan Dispenser
PRV
Cold water inlet with
15mm Stop tap
by plumber
Filter
system
10 amp plug in
power supply
SC80 chiller
unit
Power cord
Drained safe tray
of cabinet
Warm air outlet vent
in door of cabinet
CO2 regulator
CO2 black 6mm tube
Chilled water to tap blue 1/4” tube
Soda water
to regulator
white 1/4” tube
Soda water to tap
Soda regulator
white 1/4” tube
cold water supply to
chiller blue 1/4” tube
Typical installation layout
In situations where any water leakage could result in damage to property, the
complete Schwan installation should be installed over a Drained Safe Tray,
plumbed to an appropriate drainage connection.
WARNING
NOTE
Allow a minimum of 100mm air space around the sides,
back and the front of the chiller.
Cabinet must be vented to provide air flow, see venting
diagram on next page.
The filter system and CO2 bottle must be easily accessible
for routine maintenance and changing.
The filter must be less than 600mm from the chiller inlet.
Use no more than 800mm of 1/4” water supply tube from
stop tap to chiller inlet.
Tap base must be within 700mm of chiller outlet
•
•
•
•
•
•