ENGLISH
TP-54 Solo / TP-54 Twin
- 16 -
7 Maintenance
To ensure a permanent undisturbed operation of the
pneumatic components, TP-54 Solo / TP-54 Twin
includes a compressed air filter. This filter collects
excessive water (which results from compressing air)
into a collection container. Empty this collection tray as
soon as a visible amount of water has formed.
To empty the collection container, the first step will be to
remove the compressed air piping. Afterwards turn the
drain valve (like demonstrated in the picture), and the
water will run out.
To close the drain valve again, pull it down and
simultaneously turn it (like in the image demonstrated
direction).
8 Problem Solving
Problem
Reason
Removal
1. Compressed air pipe is not
connected.
Connect the compressed air pipe with the
compressed air filter (Ch. 3)
2. Compressor is turned off
Turn on the compressor
3. Pressure regulator is closed
Turn the pressure regulator to the left
(Ch. 4.2)
4. Sliding table is not in end
position
Push the sliding table until it blocks
(Ch.5)
5. Start buttons didn’t get pushed at
the same time
Push the start buttons both at the same
time (Ch. 5)
Transfer press does not work after
pushing the start button
6. Pushed the emergency stop
Open the emergency stop
After the printing process started,
the heat element lowers but returns
immediately into is original
position.
Work plate was set up to low/ the
gap between heat element and
work plate is too wide.
Raise the work plate, clearance max. 25
mm (Ch. 4.1)
Work plate is twisting
Height
is
not
adjusted
or
insufficient locked in place.
Arrange the work plate and lock the right
height adjustment through turning the
clamp knob to the right - until the work
plate is not twistable anymore. (Ch. 4.1)
drain valve
1
2
collecting tray