34
PUMP OvERRUN
Continue with the modification of parameters by pressing
the -
(MINUs)
Repeat the operations A-B-C to change value
VALUE
FROM
TO
DEFAULT
1
min
10 min
5
min
sETTING OF THE MINIMUM HEATING TEMPERATURE
Continue with the modification of parameters by pressing
the -
(MINUs)
Repeat the operations A-B-C to change value
VALUE
FROM
TO
DEFAULT
20 °C
60 °C
35 °C
sETTING OF THE MINIMUM DHw TEMPERATURE (only
if combined with an external storage tank)
Continue with the modification of parameters by pressing
the -
(MINUs)
Repeat the operations A-B-C to change value
VALUE
FROM
TO
DEFAULT
35 °C
45 °C
40 °C
sETTING OF THE MAXIMUM HEATING TEMPERATURE
Continue with the modification of parameters by pressing
the -
(MINUs)
Repeat the operations A-B-C to change value
VALUE
FROM
TO
DEFAULT
65 °C
85 °C
80 °C
sETTING OF THE MAXIMUM DHw TEMPERATURE (only
if combined with an external storage tank)
Continue with the modification of parameters by pressing
the -
(MINUs)
Repeat the operations A-B-C to change value
VALUE
FROM
TO
DEFAULT
50 °C
65 °C
60 °C
MODULATING PUMP MINIMUM MODULATION LEvEL
Continue with the modification of parameters by pressing
the -
(MINUs)
Repeat the operations A-B-C to change value
VALUE
FROM
TO
DEFAULT
BWA 50
BWA 70
0 %
99 %
19
25