Assembly
02.00|WDB 99 |en
43
WDB 99-50 base module or the WDG 99-50 basic module. The air
connection can be closed with the locking screw included in the
scope of delivery. Otherwise, the WDA 99-70 compensation mod-
ule has a sealing element for this, which closes the air supply
against the upcoming system pressure to the base module.
When controlling the NSE plus 99 quick-change pallet systems and
the WDA 99-70 D36 compensation module, the following must be
observed:
unlocking function, turbo function:
• Max. pressure 6 bar
Workpiece system control (only with WDN 99-70 direct clamping
module) see chapter: "Function of the workpiece system control"
• Max. pressure 2 bar
• Limit volumetric flow to 15 l/min
Pneumatic circuit diagram