Disassembly
34
05.00|1411420_NSE-HT mini 88-20, NSE-HT mini 88-20-V1 |en-US
Disassembly
If the product is to be removed from the installation space, there
are two procedures for disassembly:
Using clamping pins (preferred method):
1 Unlock the product (
← →
)
2 Insert clamping pin (SPA or SPB mini 20)
3 Lock product, disconnect power supply
4 Remove cover plugs (item 6) (e.g. by re-boring), remove
mounting
screws (item 17).
5 Screw the M8 screw into the clamping pin and pull out the
product by the screw. If the product cannot be pulled out, use a
long M8 screw to press the product out. Continue to screw the
screw into the clamping pin until the pin presses against the
installation space or machine table and lifts the product.
6 If disassembly is successful, the base-side unlocking connection
can be pressurized with compressed gas using a compressed air
pistol so that the clamping pin can be removed again.
Using detaching or forcing threads in the product
M5 threads are provided on two of the six countersunk screws for
the mounting screws (item 17). These can also be used to
disassemble the product:
1 Disconnect the power supply
2 Remove cover plugs (item 6), remove mounting screws (item
17).
3 Screw M5 eye bolts or similar connecting elements into the
threads and pull the product out of the installation space.
If the product cannot be pulled out:
4 Insert cylindrical elements Ø4 x 12 mm (e.g. cylindrical pins)
into the holes with the M5 thread.
5 Screw M5 screws into the threads and press the product
against the cylindrical elements.
7