Maintenance and care
8.2 TOOLFIX VARIO basic module
Monthly: Visual and functional inspection and cleaning of the
quick-change interface for tool adapters:
1. Remove the engaged tool adapter from the quick-change
interface (1).
2. Clean the interface and visually inspect it for damage or
increased signs of wear.
3. Actuate the release mechanism several times and observe the
quick-change interface (1). When the release mechanism is
actuated, a selector shaft in the center of the quick-change
interface (1) moves in and out axially.
4. Measure the axial stroke of the selector shaft. Set value: 4.7
mm ± 0.3 mm
5. Now insert a tool adapter into the quick-change interface (1)
without actuating the release mechanism. Slide the tool
adapter into the basic module up to the stop and measure the
distance shown. Nominal dimension: 12.5 mm.
6. Activate the release mechanism and slide the tool adapter 2 - 3
mm further.
33