Maintenance and care
30
04.00 | KSP3, KSP3-LH, KSP3-F | TANDEM Clamping Block | en | 1463318
Central lubrication
• To use central lubrication, the set-screws of
the factory sealed connections (6, 7) must be
removed.
• For proper lubrication, both supply lines
must be connected.
• The central lubrication system must be
suitable for greases of NLGI 2 classification.
• Only lubricate in the open position.
• After greasing, run through the complete
stroke several times.
• Grease to be used and lubrication
intervals,
Size
Grease quantity (per connection) [cm³]
64
2
100
4
140
4
160
4
200
4
250
4
315
6
7.4.2 Basic cleaning
WARNING
Risk of injury during disassembly of the product because of the
high spring pressure in the cover and the cylinder pistons (AS
variant).
•
Only trained specialist personnel may disassemble the
clamping force block!
•
The cover may only be removed with the aid of a suitable
disassembly device!
For basic cleaning, the product must be disassembled, cleaned and
reassembled. With the "PM" variant, the pneumatic jaw end
position control must also be set.