Maintenance and care
28
04.00 | KSP3, KSP3-LH, KSP3-F | TANDEM Clamping Block | en | 1463318
7 Maintenance and care
7.1 Notes
Original spare parts
Only use original spare parts from SCHUNK when replacing
wearing parts/spare parts.
Replacement of the housing and base jaws
The base jaws and the guides in the housing are matched to each
other. To replace these parts, send the entire product to SCHUNK
with a repair order.
Maintenance variant with clamping force maintenance (AS)
The cylinder piston must be disassembled or assembled using a
disassembly and assembly device. We therefore recommend you
have maintenance work and change of seals performed at
SCHUNK.
7.2 Maintenance and lubrication intervals
The following maintenance work should be carried out after the
specified cycle numbers or at the latest after the monthly data.
Maintenance work
Interval [cycles/month]
Lubricate
10,000 / 1
Basic cleaning
- / 6
Leak test
5,000 / 1
7.3 Greasing areas / lubricants
Greasing areas
Lubricant
Sliding surfaces body – base
jaw
microGLEIT LP 410
Sliding surfaces base jaws –
chuck piston
microGLEIT LP 410
Lubrication nipple
microGLEIT LP 410
Central lubrication
microGLEIT LP 410
All seals
RENOLIT HLT 2
Sliding surfaces cylinder piston
– housing
RENOLIT HLT 2
(Product information about microGLEIT LP 410 can be requested
from SCHUNK).
Alternative lubricant
LINOMAX plus can also be used as an alternative to microGLEIT LP
410. However, the specified clamping forces exclusively refer to
the microGLEIT LP 410 used by SCHUNK. When using LINOMAX
plus, the clamping forces can be lower.