Maintenance and care
30
01.00|KSH3, KSH3-LH, KSH3-F |en
Central lubrication
• To use central lubrication, the set-screws of
the factory sealed connections (6.7) must
be removed.
• For proper lubrication, both supply lines
must be connected.
• The central lubrication system must be
suitable for greases of NLGI 2 classification.
• Only lubricate in the open position.
• After greasing, run through the complete
stroke several times.
• Grease to be used and lubrication intervals,
Size
Grease quantity (per connection) [cm³]
64
2
100
4
140
4
160
4
250
4
Basic cleaning
For basic cleaning, the product must be disassembled, cleaned and
reassembled. With the "PM" variant, the pneumatic jaw end
position control must also be set.
Before disassembling the product, switch off the machine and
secure it against being switched on again. Then remove all
hydraulic lines. No residual energy may be left in the product.
7.4.2
Disassembly