Operation
36
03.00|Clamping device SVP-Mini auto/SVP-RM auto|en
Solving problems with clamping and loosening the tool
CAUTION
Risk of injury due to sharp-edged tools.
• Wear protective gloves at tool change.
The tool cannot be inserted into the jaw chuck:
1 Clean tool shank.
2 Remove possible elevations of the material from the tool shank,
which may be caused by engraved inscriptions.
When the target pressure is reached, the tool cannot be clamped or
loosened:
1 Cancelling the clamping procedure: Push the "-" button on the
remote control.
2 Remove the polygonal jaw chuck.
3 Turn the polygonal jaw chuck by 120° and push it into the inter-
mediate sleeve.
OR: Push the polygonal jaw chuck through the other side into the
intermediate sleeve.
4 Repeat the clamping procedure.
The tool becomes stuck in the polygonal jaw chuck:
The tool can become stuck as a result of fine particles in the cooling
lubricant
1 Insert a piercer through the rear opening of the polygonal jaw
chuck.
2 Loosen the tool by pushing or gently hitting it with the piercer.
6.4