Maintenance
40
10.00 | SRU | Assembly and Operating Manual | en | 389439
8.3 Lubricants/Lubrication points (basic lubrication)
SCHUNK recommends the lubricants listed.
During maintenance, treat all greased areas with lubricant. Thinly
apply lubricant with a lint-free cloth.
Lubricant point
Lubricant
The teeth and the pinion
Molykote BR 2 plus
Metallic sliding surfaces
Renolit HLT 2
All seals
Renolit HLT 2
8.4 Disassembly and assembly
8.4.1 Dismantle product
Position of the item numbers
WARNING
Risk of injury when machine/system moves unexpectedly!
•
Switch off power supply before assembly and installation.
•
Make sure that no residual energy remains in the system.
Ø
Remove the compressed air hoses.
Ø
Unscrew the screws (34) and remove the cover 1 (3).
Ø
Unscrew the screws (60) and remove the cover 2 (14).
Ø
Mark the installation position of the piston (2) and the pinion
(6 / 16).
Ø
Version with media feed-through: Unscrew the screws (41) and
remove the cover (18).
Ø
Disassemble the safety ring (33) on the pinion.
Ø
Type SRU 8 and Type SRU 10: Remove the washer (7).
Ø
Press the pinion (6 / 16) upward out of the housing (1).
Ø
Servicing the module.