Function
02.00|0889073_ROTA TB-TBS-EP |en
45
transfer point. This allows low-loss flow of the air through the
openings in the profile seal into the cylinder chamber of the chuck.
If the supply of compressed air is stopped, the double check valve
closes and the pre-tensioned profile seal raises from the chuck
body due to its elasticity and is not subjected to wear during
rotation of the chuck. The off- and return air out of the opposit
cylinder chamber leaves for the most part directly below the
associated profile sealing.
CAUTION
During actuation of the clamping device (clamping or releasing)
it must be ensured that a short ventilation time is maintained
between the switching processes. This ventilation time must last
at least 0.5 seconds, depending on the hose length. For this
purpose we recommend the use of a 4/3- or 5/3- way valve
(central position depressurized).
Содержание ROTA EP 380-127
Страница 64: ...Assembly drawings 64 02 00 0889073_ROTA TB TBS EP en Assembly drawings TB 400 850 16 ...
Страница 65: ...Assembly drawings 02 00 0889073_ROTA TB TBS EP en 65 TB 400 850 LH Item for TB 400 115 and TB 400 140 ...
Страница 66: ...Assembly drawings 66 02 00 0889073_ROTA TB TBS EP en TB 400 850 LH ...
Страница 67: ...Assembly drawings 02 00 0889073_ROTA TB TBS EP en 67 X Clamping stroke TB 1000 LH ...
Страница 68: ...Assembly drawings 68 02 00 0889073_ROTA TB TBS EP en ...
Страница 69: ...Assembly drawings 02 00 0889073_ROTA TB TBS EP en 69 EP LH ...
Страница 70: ...Assembly drawings 70 02 00 0889073_ROTA TB TBS EP en ...