Positioning the
magnetic switch
Gripper open:
Ø
Set the gripper to "open" position.
Ø
Push magnetic switch 1 (1) into the groove (4) until it stops at
the housing.
Ø
Pull magnetic switch 1 (1) back again slowly until it switches.
Ø
Tighten the set-screw (3) on the magnetic switch to clamp
magnetic switch 1 (1) in this position in the groove (4).
Ø
Close the gripper and open it again in order to test its function.
Gripper closed:
Ø
Set the gripper to the "closed" position.
Ø
Push magnetic switch 2 (2) into the groove (3) towards the
middle of the gripper until it switches.
Ø
Tighten the set-screw to clamp magnetic switch 2 (2) in this
position in the groove (3).
Ø
Open the gripper and close it again to test its function.
Part gripped (O.D. gripping):
Ø
Clamp the part to be gripped.
Ø
Push magnetic switch 2 (2) into the groove (3) towards the
middle of the gripper until it switches.
Ø
Tighten the set-screw to clamp magnetic switch 2 (2) in this
position in the groove (3).
Ø
Open the gripper and close it again to test its function.
Part gripped (I.D. gripping):
Ø
Clamp the part to be gripped.
Ø
Push magnetic switch 1 (1) into the groove (4) until it stops at
the housing.
Ø
Pull magnetic switch 1 (1) back again slowly until it switches.
Ø
Tighten the set-screw to clamp magnetic switch 1 (1) in this
position in the groove (4).
Ø