The sensors can be set to the following switching positions:
Position "Gripper open"or"Part gripped (I.D. gripping)":
Ø
Bring product in the position in which it is to be set.
Ø
Loosen screw (8), so that the control cam 1 (9) can be moved in
the bracket (7).
Ø
Slide the control cam 1 (9) to the free end of the bracket.
Ø
Push control cam 1 (9) back until the sensor 1 (1) switches.
Ø
Tighten screw (8), in order to fix the control cam in this position.
Ø
Bring product into the "Gripper open" or "Part gripped" position
and test the function.
Position "Gripper closed"or"Part gripped (O.D. gripping)":
Ø
Bring product in the position in which it is to be set.
Ø
Loosen screw (8), so that the control cam 2 (9) can be moved in
the bracket (7).
Ø
Slide the control cam 2 (9) to the free end of the bracket.
Ø
Push control cam 2 (9) back until the sensor 2 (2) switches.
Ø
Tighten screw (8), in order to fix the control cam in this position.
Ø
Bring product into the "Gripper closed" or "Part gripped"
position and test the function.