Assembly
24
10.00 | PSH | Assembly and operating manual | en | 389331
5.3.3 Mounting inductive proximity switch IN 80
Free milling for
inserting
the T-nuts
Proximity
switch 1
Proximity
switch 2
Control cam 1
Control cam 2
Size
Distance X
[mm]
Distance Y
[mm]
Distance Z
[mm]
PSH 22/1
22.5
-
8.0
PSH 22/2
15.5
-
1.0
PSH 32
- 2.0
30.0
18.0
PSH 42
3.0
36.0
23.5
PSH 52
12.0
40.0
0.0
To be able to mount the sensor, the gripper has to be retrofitted
with a special mounting kit.
Ø
Mount the bracket (7) with screws (6) on the base jaw so that
the bracket (7) is above the groove (12) in the housing. Only
screw in screws (6) until the bracket (7) can still be turned
without play.
Ø
Secure the screws (6) with Locite No. 243.
Ø
Place control cams (9) into the oblong hole in the bracket (7)
and secure to the bracket using screws (8).
Ø
Push T-nuts (5) into the groove (12) (for PSH 22 only one T-nut (5)).
Ø
Secure guide piece (10) with screw (11) to T-nut (5), so that the
guide piece (10) can still be pushed further into the groove (12).
Ø
Fasten the bracket (3) with screws (4) to the T-nuts (5). Only
screw in screws (4) until the brackets (3) can be pushed further
into the groove (12) (for PSH 22 only one bracket (3)).
Ø
Screw sensors (1, 2) into the brackets (3) only until they are
flush against the brackets.
Ø
Push brackets (3) and guide piece (10) to the positions "X", "Y"
and "Z", for clearance measurements see previous table.
Ø
Tighten the screws (4).