Assembly
06.00 | PPU-P | Assembly and Operating Manual | en | 389323
19
4 Assembly
4.1 Mechanical connection
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
Mounting
Mounting of the unit
The unit must be mounted on the floor space below.
The following mounting materials are necessary for installation of
the unit and must be provided by the customer:
Mounting material
Item Designation
PPU-P 10
PPU-P 30
1
Screw ISO 4762
M8 / 2x
M10 / 4x
2
Cylindrical pin ISO 8734
Ø5m6 / 2x
Ø6m6 / 2x