Assembly
16
07.00 | PHL | Assembly and Operating Manual | en | 389508
4 Assembly
4.1 Mechanical connection
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
Evenness of the
mounting surface
The values apply to the whole mounting surface to which the
product is mounted.
Requirements for evenness of the mounting surface (Dimensions in mm)
Edge length
Permissible unevenness
< 100
< 0.02
> 100
< 0.05
Mounting
The module can be mounted in 2 different ways:
• A: Screws (1) are screwed through the housing.
• B: Screws (2) are screwed in the thread.
The centering sleeves (3) are included in the accessory kit.
CAUTION
Observe the minimum depth of engagement during assembly.
•
The minimum depth of engagement is equal to 1.5 times the
thread diameter.