Assembly
07.00 | PHL | Assembly and Operating Manual | en | 389508
23
4.4.3 Magnetic switch MMS 22 / RMS 22
CAUTION
Material damage due to an incorrect tightening torque!
If the threaded pin is tightened with an incorrect tightening
torque, the product may be damaged.
•
Observe a maximum tightening torque of 10 Ncm for the set-
screws.
NOTE
Ferromagnetic material changes the switching positions of the
sensor. For example: Adapter plate made of ordinary steel.
At ferromagnetic adapter plates:
• First mount the product on the adapter plate.
• Then set the position of the magnetic switch.
The RMS sensors have a larger hysteresis than the MMS sensors.
This means that short gripper strokes may not be able to be
monitored with the RMS sensors.
Positioning the
magnetic switch
Positioning the magnetic switches
Gripper open:
Ø
Set the gripper to the "Open" position.
Ø
Slide the magnetic switch (1) from the side closer to the jaw
from the front into one of the grooves until the proximity switch
switches.
Ø
Clamp the magnetic switch (1) in the groove in this position by
tightening the set-screw.
Ø
Close the gripper and open it again in order to test its functioning.
Gripper closed:
Ø
Set the gripper to the "Closed" position.
Ø
Slide the magnetic switch (2) from the side closer to the jaw from the
front into one of the grooves until the proximity switch switches.
Ø
Clamp the magnetic switch (2) in the groove in this position by
tightening the set-screw.
Ø
Open the gripper and close it again to test its functioning.