Assembly
18
04.00 | PGM 29 - 140 | Assembly and Operating Manual | en | 389284
Ø
To relieve the cable, the electronics have to be fixed in place
using cable ties (7).
There are ribs (6) in place on the electronics for mounting
purposes.
Ø
Turn in the sensor (1 - 4).
OR
Push the sensor axially into the slot until it contacts the stop (5).
Ø
Fix the sensor with an Allen wrench (6).
Ø
Keep the Teach-Button (4) pressed for 2 seconds.
✓
After 2 seconds flashing LED 1 (3).
Ø
Move the gripper into position 1 (e.g. "0 - position").
Ø
Press the Teach-Button (4) briefly.
✓
LED 1 (3) lights up and LED 2 (5) is flashing.
Ø
Move the gripper manually into position 2 (e.g. "-2mm").
✓
LED 1 (3) should turn out as soon as the switching point 1 is
left.
Ø
Press the Teach-Button (4) briefly.
✓
LED 2 (5) lights up.
✔
The switching points are set.