![SCHUNK MWS 20 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/schunk/mws-20/mws-20_assembly-and-operating-manual_1215958030.webp)
Troubleshooting
30
03.00 | MWS | Assembly and Operating Manual | en | 389230
7 Troubleshooting
7.1 The system cannot be connected?
Possible cause
Corrective action
The actuating ring is set to “close”.
The locking elements of the system
are blocking the MWK.
Turn the actuating ring on the lever to the "open"
position and connect the system
7.2 The system cannot be locked by the actuating ring?
Possible cause
Corrective action
There is a gap between the MWK
and the MWA and the system
cannot be locked correctly.
Switch off the power supply and check to ensure that:
• the screws were mounted at the correct position.
• the groove on the MWK is lined up with the groove
on the MWA.
• all o-rings were inserted correctly and are flush
with the housing.
7.3 No signal is arriving at the tool?
Possible cause
Corrective action
The electrical contact is
interrupted.
Check to ensure that:
• the markings line up.
• the voltage supply to the system is sufficient.
• the electrical connections were soldered correctly,
and shrink tubing are mounted so that short
circuits are avoided.
7.4 Air is escaping from the MWS?
Possible cause
Corrective action
There is a leak in the system.
Switch off the power supply and check to ensure that:
• the markings line up.
• all o-rings were mounted / are still present.
• all o-rings were mounted at the right position.