Maintenance
14. Insert wedge hook (1) into the housing (10).
15. Insert the cylinder piston (4) into the housing (10) and while
doing so, observe the installation position of the
magnets,
.
16. Tighten screw (8). Secure the screw with medium-strength
threadlocker.
Tightening torque:
17. Insert spring (7) into the housing (10). In doing so, observe the
alignment of the spring in relation to the cylinder piston.
18. Insert flat gasket (6).
19. Fasten the cover (5) with the screws.
Tightening torque:
20. Fasten the cover (11) with the screws.
21. Mount product onto the system/machine.
22. Connect all compressed air lines.
7.6 Installation position of the magnets in the piston
The installation position of the piston in the housing depends on
the size and variant. The magnets (1) attached to the piston can
either point upwards (A) or downwards (B).
Installation position of the piston in the housing, A: Magnet (1) above, B: Magnet
below
Size
A
B
Variant without maintenance of gripping force
JGP-P 40
x
-
JGP-P 50 - 240
-
x
JGP-P 300
-
x
Variant with "O.D. gripping" maintenance of gripping force
JGP-P 40 O.D.
x
-
JGP-P 50-125 O.D.
-
x
55
02.00 | JGP-P | Assembly and Operating Manual | en | 1469637