Damping adjustment
end position
retracted (right view)
1. Remove the stop screw (1) from the plate and undo the counter
nut (3).
2. Set the setscrew (2) to the desired dimension. ! Caution,
observe the setting range. (See below)
3. Tighten the setscrew (2) and reinstall the stop screw (1) in the
plate.
Damping adjustment
end position
extended (left view)
1. Undo the attachment screw.
2. Set the damping adjustment setscrew to the desired dimension.
Caution, observe the setting range.
3. Secure the setscrew again with the attachment screw.
Linear module
Damping adjustment dimension Z
HLM 025
-1.3...0 mm
HLM 050
0...+1.8 mm
HLM 100
-0.6...+2.4 mm
HLM 200