Maintenance
36
02.00 | GWB | Assembly and Operating Manual | en | 389122
6.4.2 Disassembling the GWB 100 module
Position of the item numbers
WARNING
Risk of injury due to unexpected movements!
If the power supply is switched on or residual energy remains in
the system, components can move unexpectedly and cause
serious injuries.
•
Before starting any work on the product: Switch off the power
supply and secure against restarting.
•
Make sure, that no residual energy remains in the system.
WARNING
Risk of injury due to spring forces!
The cover is under spring tension.
•
Carefully disassemble the product.
Ø
Remove the bar (9) with the screws (29).
Ø
Place a workpiece with a length of 64 mm between the fingers (3).
Ø
Remove the compressed air lines.