Commissioning
02.00 | EMH | Assembly and Operating Manual | en | 1393220
23
WARNING
Risk of injury due to loss of workpiece!
A holding force that is too low can lead to the loss of a workpiece
and serious injuries during handling.
•
Test workpiece suitability for each type of workpiece separately.
•
Increase the holding force if necessary.
•
Observe the maximum permissible load capacity,
14].
•
Avoid overheating the product. If necessary, reduce the
number of activations per minute.
6.1 Adjusting the holding force
The required holding force is adjusted before each magnetization
by the system-side setting (value = 1) or by turning off (value = 0)
the force signals A and B:
Selecting the holding force level
Holding force level
Percentage of
max. holding force
Force signal
A *
Force signal
B *
Holding force level 1
approx. 15%
1
1
Holding force level 2
approx. 25%
1
0
Holding force level 3
approx. 35%
0
1
Holding force level 4
100%
0
0