Assembly
20
02.00 | EMH | Assembly and Operating Manual | en | 1393220
Mounting screws
Item Designation
EMH
36-B
45-B
84-B
114-B
1
Mounting screws (4 x)
Thread
M6
M6
M10
M10
Maximum depth of
engagement [mm]
20
20
20
20
Mounting screw strength
class
8.8
2
Centering sleeves (2 x)
Ø10
Ø10
Ø14
Ø14
5.3 Electrical connection
CAUTION
Damage due to faulty connection!
A faulty connection can cause damage to the product.
•
Observe the pin allocation of the connecting terminals.
•
Make sure that all components are grounded correctly.
Electrical connection
Ø
Screw the grounding cable into the ground connection (1).
Ø
Connect the socket of the logic cable to the logic connection (2).
Ø
Connect the socket of the power cable to the power connection (3).
The cables are not included in the scope of delivery, for
permissible cable specifications, see catalog data sheet EMH.